Download Print this page
BW SENSING DIS342 Series Technical Manual

BW SENSING DIS342 Series Technical Manual

Relay dual-axis inclination switch

Advertisement

Quick Links

DIS342
Series
Relay Dual-Axis
Inclination Switch
Technical Manual

Advertisement

loading

Summary of Contents for BW SENSING DIS342 Series

  • Page 1 DIS342 Series Relay Dual-Axis Inclination Switch Technical Manual...
  • Page 2 Relay Dual-Axis Inclination Switch Introduction Designed by Bewis Sensing Technology LLC, The DIS342 series is a dual-axis inclination switch, with a measuring range of ±90°. When the measured inclination angle exceeds the alarm threshold, the output line becomes closed (disconnected is also available). If the measured inclination does not exceed the alarm threshold, the output line is normally open (also normally closed).
  • Page 3: Electrical Specifications

    DIS342 Relay Dual-Axis Inclination Switch Specifications Electrical Specifications Product number DIS342 Typical Power Supply (V) Conditions Non-loaded Operating current(mA) 40(DC12V) Operating temperature(°C) +100 Store temperature(℃) <±90 Measuring range(°) dynamic 2°/ Static 0.1° Accuracy(°) 0.01 Resolution(°) Measuring axis X、Y Alarm axis X、Y Zero temperature ±0.01...
  • Page 4 DIS342 Relay Dual-Axis Inclination Switch Mechanical Characteristic Metal connector(standard cable is 1.5m) Connector Protection level IP67 Magnesium alloy anodizing Shell material Installation Three M4 screws Package size Product Size:L103.8*W55.4*H26(mm) Aviation connector:116 Metal connector:105 Top view Bare plate product size Product size: L69*W49*H12(mm) Note: ±1mm error for length and width dimensions, please refer to actual size.
  • Page 5: Installation Direction

    DIS342 Relay Dual-Axis Inclination Switch Installation direction The correct installation method can avoid measurement error. The following points should be made when installing the sensor: First of all, to ensure that the sensor mounting surface and the measured surface completely close, the measured surface should be as horizontal as possible, can not have the angle shown in Figure A and Figure C, the correct installation is shown in Figure B and Figure D.
  • Page 6: Electrical Connections

    DIS342 Relay Dual-Axis Inclination Switch Electrical Connections Electrical interfaces WHITE ORANGE BLACK PURPLE BEOWN Cable color YELLOW GREEN & Function U YOUT U XOUT DC 9-35V BROWN 9~35V ORANGE U YOUT GREEN YELLOW WHITE PURPLE U XOUT BLACK Tel:+86 189 0617 7922 Bewis Sensing Technology LLC www.bwsensing.com...
  • Page 7 DIS342 Relay Dual-Axis Inclination Switch Debug software Users can directly download serial assistant on official website (Supports-Download). You can also use more convenient and intuitive PC software. DIS342 supporting serial debugging software can be connected to the inclinometer on the computer for angle display.
  • Page 8 DIS342 Relay Dual-Axis Inclination Switch Protocol 1 Data Frame Format: (8 data bits,1 stop bit,No parity check,default baud rate 9600) Identifier Data Frame Length Command Address Code Checksum (1byte) (1byte) (1byte) (1byte) (Nbyte) (1byte) 0x77 Data Format: Hexadecimal Identifier: Fixed to 77(partly 68) Frame Length: Length from Frame Length to Checksum(included)...
  • Page 9 DIS342 Relay Dual-Axis Inclination Switch 2.3 Read angle of X,Y axis Command:77 04 00 04 08 Identifier Data Frame Length Checksum Address Code Command (1byte) (0byte) (1byte) (1byte) (1byte) (1byte) 0x77 0x08 0x04 0x04 Command response: Data Identifier Frame Length Address Code Command Checksum...
  • Page 10 DIS342 Relay Dual-Axis Inclination Switch 2.4 Set address module Command: 77 05 00 0F 01 15 Frame Length Command Identifier Address Code Data Checksum (1byte) (1byte) (1byte) (1byte) (1byte) (1byte) 0xXX 0x05 0x77 0xYY 0x0F Command response: Address Code Command Frame Length Checksum Identifier...
  • Page 11 DIS342 Relay Dual-Axis Inclination Switch 2.7 Set the zero type Command:77 05 00 05 01 0B Identifier Data Frame Length Address Code Checksum Command (1byte) (1byte) (1byte) (1byte) (1byte) (1byte) 0x00: absolute zero 0x77 0x05 0x05 0x01: relative zero Command response: Identifier Address Code Frame Length...
  • Page 12 DIS342 Relay Dual-Axis Inclination Switch 2.10 Quer y alarm angle Command: 77 05 00 21 00 26 Data Identifier Address Code Command Frame Length Checksum (1byte) (1byte) (1byte) (1byte) (1byte) (1byte) 0x00:+X 0x01:+Y 0x77 0x05 0x21 0X02:-X 0X03:-Y Response command: Command Data Identifier...
  • Page 13 DIS342 Relay Dual-Axis Inclination Switch 2.13 Set alarm delay off time Command: 77 07 00 23 01 05 00 30 Data Identifier Address Code Frame Length Checksum Command (1byte) (1byte) (3byte) (1byte) (1byte) (1byte) 0x77 0x07 0x23 DXXYY Response command: Identifier Data Frame Length...
  • Page 14: Ordering Information

    DIS342 Relay Dual-Axis Inclination Switch Ordering Information Package condition Product number Way of communication RS232 DIS342-232 IP67 Package/Metal Connector DIS342-TTL IP67 Package/Metal Connector Executive standard ● Enterprise Quality System Standard: ISO9001:2008 Standard (Certificate No.:10114Q16846ROS) ● CE certification (certificate number: 3854210814) ●...
  • Page 15 DIS342 Relay Dual-Axis Inclination Switch Wuxi Bewis Sensing Technology LLC Address: Building 30, No. 58 Xiuxi Road, Binhu District, Wuxi City Hotline: 400-618-0510 Tel: +86 510 85737178-801 Email: sales@bwsensing.com Website: www.bwsensing.com...