Function Description - Toshiba 37AV504D Service Manual

Lcd color television
Table of Contents

Advertisement

To return Bus on status, press and hold the CALL button on the remote control, then press
the Volume
+ button on the TV again. TV will be turned off and automatically turned
on, then status will be Bus On.
Setting TVOP
Enter to service mode and select menu of TVOP by pressing P
adjustment menu. After selecting TVOP, press
disable or enable as below.
TVOP

FUNCTION DESCRIPTION

D5 (bit5) I2C check between IC700 and IC400. (WDT) Disable Enable
Setting Panel Option Data
Panel option data is subject to OP4 and OP5.
Enter to service mode and select menu of OPT4 or OPT5 by pressing P
display of adjustment menu. After selecting OPT4 or OPT5, press
or OPT5 value as table below.
Panel option data
Series
A505D
EU Digital
OP4
Ex. OPT4 value 0x05 indicates that panel vendor is AUO AMVA.
Model name
32AV503D/504D/505D IPS
37AV503D/504D/505D IPS
42AV503D/504D/505D
or P
+ or
- to set I2C check function to
1
0 (Normal)
+ or
Panel vendor OPT4 value OPT5 value
0x07
0x07
LPL
0x01
AUO
0x05
during display of
or P
during
- to set OPT4
0x65
0x66
0x67
0x87

Advertisement

Table of Contents
loading

Table of Contents