Maintenance 13.1 Pre-adjustment of the active return 13.2 Adjustment of the forced return 13.3 Lubrication Appendix 14.1 Internet and CAD STRACK NORMA GmbH & Co. KG · Königsberger Str. 11 · D-58511 Lüdenscheid · Tel +49 2351 8701-0 · www.strack.de...
Page 3
14.6 Calculations gas springs 14.7 Installation instructions gas springs 14.8 Filling pressure table gas springs Exploded view and parts list STRACK NORMA GmbH & Co. KG · Königsberger Str. 11 · D-58511 Lüdenscheid · Tel +49 2351 8701-0 · www.strack.de...
If the regulations and notes of these operating instructions are not considered, any liability on our part for resulting damages and loss of performance is excluded. STRACK NORMA GmbH & Co. KG · Königsberger Str. 11 · D-58511 Lüdenscheid · Tel +49 2351 8701-0 · www.strack.de...
Damaged gas springs must not be reused. The exchange of individual components has to be discussed with STRACK NORMA. STRACK NORMA GmbH & Co. KG · Königsberger Str. 11 · D-58511 Lüdenscheid · Tel +49 2351 8701-0 · www.strack.de...
The design and the resulting values such as installation height and return forces require that the cam unit is installed in the specified front-end position. STRACK NORMA GmbH & Co. KG · Königsberger Str. 11 · D-58511 Lüdenscheid · Tel +49 2351 8701-0 · www.strack.de...
5, in all intermediate angles according to customer requi- rements. Please contact us. STRACK NORMA GmbH & Co. KG · Königsberger Str. 11 · D-58511 Lüdenscheid · Tel +49 2351 8701-0 · www.strack.de...
Attention: If the cam is to be built over with attachments, a new calculation is necessary. Please contact us. STRACK NORMA GmbH & Co. KG · Königsberger Str. 11 · D-58511 Lüdenscheid · Tel +49 2351 8701-0 · www.strack.de...
If the heights h1 and h2 (see figure below) in the tool are reduced, the forces of the shouldering cannot be fully born. For exact details, please refer to the catalogue information for your cam on the internet www.strack.de STRACK NORMA GmbH & Co. KG · Königsberger Str. 11 · D-58511 Lüdenscheid · Tel +49 2351 8701-0 · www.strack.de...
• Set dowel pin Direction of fine adjustment possible before pinning in both positions End position fixed by dowel pin STRACK NORMA GmbH & Co. KG · Königsberger Str. 11 · D-58511 Lüdenscheid · Tel +49 2351 8701-0 · www.strack.de...
Can be moved longitudinally for fine positioning • Dowel pin sets final position Direction of fine adjustment End position is determined by dowel pin STRACK NORMA GmbH & Co. KG · Königsberger Str. 11 · D-58511 Lüdenscheid · Tel +49 2351 8701-0 · www.strack.de...
SNS-sintered metal. Normally a lubrication is not necessary. If necessary, a lubrication can only be carried out according to chapter 13 Maintenance. STRACK NORMA GmbH & Co. KG · Königsberger Str. 11 · D-58511 Lüdenscheid · Tel +49 2351 8701-0 · www.strack.de...
Installation of cam retainer with cam slide in the tool with lateral thread for flexible installation and turning of the cam. STRACK NORMA GmbH & Co. KG · Königsberger Str. 11 · D-58511 Lüdenscheid · Tel +49 2351 8701-0 · www.strack.de...
If the marking on the cam body is between those of the retainer, the whole cam is not returned to the correct starting position. STRACK NORMA GmbH & Co. KG · Königsberger Str. 11 · D-58511 Lüdenscheid · Tel +49 2351 8701-0 · www.strack.de...
Z7685 during the upward movement and signals to the machine that the cam slide is in the rearmost position. For more information on the Z7685 limit switch see the appendix. STRACK NORMA GmbH & Co. KG · Königsberger Str. 11 · D-58511 Lüdenscheid · Tel +49 2351 8701-0 · www.strack.de...
With most of the PowerMax-cams, the fixing holes are partially covered if the cam body is in the front- end position. STRACK NORMA GmbH & Co. KG · Königsberger Str. 11 · D-58511 Lüdenscheid · Tel +49 2351 8701-0 · www.strack.de...
Then screw in the locking screw (1) and tighten it with 33 Nm. ATTENTION! Use Loctite 243 medium strength to secure the Fig. 4 screw. STRACK NORMA GmbH & Co. KG · Königsberger Str. 11 · D-58511 Lüdenscheid · Tel +49 2351 8701-0 · www.strack.de...
3. As soon as the gas spring is unloaded, turn the valve to the left until the initial position is reached. The gas spring is ready for filling. STRACK NORMA GmbH & Co. KG · Königsberger Str. 11 · D-58511 Lüdenscheid · Tel +49 2351 8701-0 · www.strack.de...
M6 into the gas spring. Continue with step 3. 6. Turn the loading equipment out of the gas spring. STRACK NORMA GmbH & Co. KG · Königsberger Str. 11 · D-58511 Lüdenscheid · Tel +49 2351 8701-0 · www.strack.de...
If both slide partners are replace, the guide play must be controlled and be readjusted, if necessary. STRACK NORMA GmbH & Co. KG · Königsberger Str. 11 · D-58511 Lüdenscheid · Tel +49 2351 8701-0 · www.strack.de...
This has the advantage that the active return is in the same position after disassembly and the guide play corre- sponds exactly to the pre-adjustment. STRACK NORMA GmbH & Co. KG · Königsberger Str. 11 · D-58511 Lüdenscheid · Tel +49 2351 8701-0 · www.strack.de...
(A) and check the guide play with 0,01 mm gauge tape. To prevent the driver from tilting both sides should be tightened equally. STRACK NORMA GmbH & Co. KG · Königsberger Str. 11 · D-58511 Lüdenscheid · Tel +49 2351 8701-0 · www.strack.de...
SNS sintered metal layer 1,5 up to 2,0 mm base material steel Magnification 100:1 STRACK NORMA GmbH & Co. KG · Königsberger Str. 11 · D-58511 Lüdenscheid · Tel +49 2351 8701-0 · www.strack.de...
Page 29
Integrierter Schmierstoff / Integrated lubricant Fe+Cu+Graphit+MoS2 / Lubrifiant intégré Schmierstoffanteil / Portion of lubricant / Part 15 - 20 % du lubrifiant STRACK NORMA GmbH & Co. KG · Königsberger Str. 11 · D-58511 Lüdenscheid · Tel +49 2351 8701-0 · www.strack.de...
Page 30
Alternative recommendations optimal (if STRACK lubricants are not available): Lubricant Company oils max. °C greases max. °C STRACK NORMA GmbH & Co. KG · Königsberger Str. 11 · D-58511 Lüdenscheid · Tel +49 2351 8701-0 · www.strack.de...
The company STRACK NORMA has created an online presence for the PowerMax cam elements which is tailored to the requirements of the constructing engineers. By using the link www.strack.de you can reach the corresponding homepage. STRACK NORMA GmbH & Co. KG · Königsberger Str. 11 · D-58511 Lüdenscheid · Tel +49 2351 8701-0 · www.strack.de...
- Lorsque plusieurs contacteurs de fin de course doivent simultaneously. être commutés en même temps, utiliser impérative- ment le boîtier de raccordement Z7614. STRACK NORMA GmbH & Co. KG · Königsberger Str. 11 · D-58511 Lüdenscheid · Tel +49 2351 8701-0 · www.strack.de...
(values detailed in the technical N = _________ specifications for each model) (2 x S) + 50 S = Working stroke STRACK NORMA GmbH & Co. KG · Königsberger Str. 11 · D-58511 Lüdenscheid · Tel +49 2351 8701-0 · www.strack.de...
3. The gas spring has not been manipulated (opening the gas spring cancels the guarantee). STRACK NORMA GmbH & Co. KG · Königsberger Str. 11 · D-58511 Lüdenscheid · Tel +49 2351 8701-0 · www.strack.de...
Do not excede maximum filling pressures established for each Gas spring. Higher pressures will reduce both the gas spring service life and endanger its use. STRACK NORMA GmbH & Co. KG · Königsberger Str. 11 · D-58511 Lüdenscheid · Tel +49 2351 8701-0 · www.strack.de...