I N S TA L L AT I O N
I N S T R U C T I O N S
A D J U S T I N G
B L OW E R D I S C H A R G E
Wolf downdraft systems have an adjustable
discharge that will allow you to negotiate
ducting around floor joists and other obstacles.
The blower is shipped with the discharge
facing down.
D O W N D I S C H A R G E L E F T T O R I G H T
Adjusting the down discharge left to right will
keep the blower discharge in the down
position but allows some side-to-side adjust-
ment.
Follow these steps if the position of the blower
discharge needs to be moved left to right so
that ductwork does not interfere with floor
joists, plumbing or wiring below the unit. Refer
to the illustration below.
Place the downdraft assembly on its back
on a flat work surface.
Loosen the 4 nuts and 2 clamp channels.
Slide the blower to the desired position.
Use the supplied cover plate to close any
open space.
Tighten nuts to secure the top of blower
and use sheet metal screws through the
bottom flange to secure the bottom of the
blower.
blower
sheet metal
clamp
screw
channel
nuts
Down blower discharge adjustment
Dimensions in parentheses are in
millimeters unless otherwise specified.
D O W N T O L E F T O R R I G H T D I S C H A R G E
Substituting down discharge with left or right
discharge will switch the blower discharge
from the down position to the left or right of
downdraft assembly.
Follow these steps if it is necessary to rotate
the blower to the left or right discharge
location. Refer to the illustration below.
clamp
channel
nut
bottom
flange
cover plate
Left or right blower discharge
Place the downdraft assembly on its back
on a flat work surface.
Remove the 4 nuts and 2 clamp channels.
Carefully lift the blower and disconnect the
motor plug if necessary. Reposition the
blower and reconnect the motor plug.
Use the supplied cover plate to close any
open space.
Replace the clamp channels and use the
nuts to secure the blower in its new
position.
Use sheet metal screws through the bottom
flange to secure the bottom of the blower.
blower
sheet metal
screw
motor plug