  • Page 1 Operating instructions Button interface, 2-gang Standard Order no. 5182 00 Button interface, 4-gang Standard Order no. 5184 00 Button interface, 8-gang Standard Order no. 5188 00 Button interface, 2-gang Komfort Order no. 5192 00 Button interface, 4-gang Komfort Order no. 5194 00 Button interface, 8-gang Komfort Order no.
  • Page 2: Table Of Contents

    Button interface Table of contents Safety instructions ...................... 3 System information ...................... 3 Intended use ........................ 3 Product characteristics .....................  4 Mounting and electrical connection ..................  4 Commissioning .........................  8 Safe-state mode and master reset.................  8 Technical data ........................ 9 Accessories ........................
  • Page 3: Safety Instructions

    The device can be updated. Firmware can be easily updated with the Gira ETS Ser- vice App (additional software). The device is KNX Data Secure capable. KNX Data Secure offers protection against manipulation in building automation and can be configured in the ETS project.
  • Page 4: Product Characteristics

    Button interface Product characteristics – Depending on the variant, two, four or eight independent channels, which work as inputs or as outputs, depending on the ETS configuration – Common reference potential for all channels – Disabling of individual channels – Supply via the KNX bus, no additional supply voltage necessary Outputs –...
  • Page 5 Button interface – Document all passwords and keep them safe. ■ In secure operation: device certificate must be removed from the device and stored securely. ■ Mounting in suitable appliance box. Observe cable routing and spacing Bus connection ■ Connect bus with a KNX device connection terminal to KNX connection (1) (see figure 1).
  • Page 6 Button interface Figure 2: Maximum cable length DANGER! Danger of electrical shock when mains voltage 230 V or other external voltages are connected! Electric shocks can be fatal. Device may be destroyed. Only connect potential-free push-buttons, switches or contacts. ■ Connect push-buttons, switches, contacts, LED or NTC to enclosed connect- ing cables (4) according to the connection examples;...
  • Page 7 Button interface Figure 4: Connection example: push-button interface 4-gang Figure 5: Connection example: push-button interface 8-gang To increase the output current, outputs can also be switched parallel to each other with the same parameterization; in the example here, (see figure 6) K1- K3 are switched in parallel.
  • Page 8: Commissioning

    Button interface Commissioning Programming the physical address and application program ■ Switch on the bus voltage. ■ Press the programming button (2). The programming LED (3) lights up. ■ Program the physical address with the ETS. The programming LED goes out. ■...
  • Page 9: Technical Data

    5 s. Restoring the device to factory settings The device can be reset to factory settings with the Gira ETS Service App. This func- tion uses the firmware contained in the device that was active at the time of delivery (delivered state).
  • Page 10: Accessories

    Please submit or send faulty devices postage paid together with a fault de- scription to your responsible salesperson (specialist trade / installation company / electrical specialist trade). They will forward the devices to the Gira Service Center. Gira Giersiepen GmbH & Co. KG...
  • Page 11 Button interface www.gira.de info@gira.de 82407702 13.11.2023 11 / 11...