E. Safety
(1) Sharp Edge Requirements
There will be no sharp edges or corners on the display assembly that could cause injury.
(2) Materials
a. Toxicity
There will be no carcinogenic materials used anywhere in the display module. If toxic materials are
used, they will be reviewed and approved by the responsible InnoLux Toxicologist.
b. Flammability
All components including electrical components that do not meet the flammability grade UL94-V1 in
the module will complete the flammability rating exception approval process. The printed circuit
board will be made from material rated 94-V1 or better. The actual UL flammability rating will be
printed on the printed circuit board.
c. Capacitors
If any polarized capacitors are used in the display assembly, provisions will be made to keep them
from being inserted backwards.
F. Display quality
The display quality of the color TFT-LCD module should be in compliance with the
Innolux's Incoming inspection standard.
G. Handling precaution
The Handling of the TFT-LCD should be in compliance with the Innolux's handling principle
standard.
SPEC NO.
M T 1 9 0 AW 0 2 V. Y
PAGE
19/23