C. Optical specifications
Item
Response time
Contrast ratio
Viewing angle
Brightness (Center)
Color chromaticity(CIE)
White uniformity (9)
Cross talk
Note 1: Ambient temperature = 25°C.
Note 2: To be measured in dark room after backlight warm up 30 minutes.
Note 3: To be measured with a viewing cone of 2°by Topcon luminance meter BM-5A.
Note 4: Definition of response time:
The output signals of BM-7 are measured when the input signals are changed from "Black"
to "White" (falling time) and from "White" to "Black" (rising time), respectively. The response time
interval is between the 10% and 90% of amplitudes. Refer to figure as below.
Symbol
Condition
Tr
Tf
θ
= 0
Tr+Tf
θ
= 0
CR
CR≧10
Top
CR≧5
CR≧10
Bottom
CR≧5
CR≧10
Left
CR≧10
Right
Y
L
Wx
Wy
Rx
Ry
Gx
θ
= 0
Gy
Bx
By
δ
W
Ct
M T 1 8 5 G W 0 1 V. 0
SPEC NO.
PAGE
15/23
Specification
Min.
Typ.
Max.
-
1.5
4
-
3.5
6
-
5
10
700
1000
-
70
80
-
75
85
70
80
-
75
85
75
85
-
75
85
-
250
300
-
0.313
0.329
0.640
0.349
-0.03
+0.03
0.284
0.617
0.142
0.067
0.75
0.80
-
-
-
2%
Unit
Remark
ms
Note 4
Note 3,5
deg.
Note 3,5,7
nit
Note 3,6
Note 3
Note 3,8
Note 9