7. MAINTENANCE

NOTE: Jacks shall be maintained and repaired in accordance with the manufacturers, instructions. Such maintenance and repair shall
be carried out by qualified persons.
7.1.
STORAGE
7.1.1.
When the jack is not in use, the saddle must be in the lowest position to minimise ram and piston corrosion and stored in a dry place.
7.2.
Check whether the parts of the transmission jack are oil leakage, deformation, damage, etc. everyday.
7.3.
When refilling the hydraulic system, the characteristics of the hydraulic fluid used in the jack and the level of hydraulic fluid as it is given
by the manufacturer shall be observed
7.4.
Keep the jack clean and wipe off any oil or grease. Lubricate all moving parts with acid free oil. Clean exposed areas with a clean oiled
cloth.
7.5.
The oil cylinder is a sealed unit and must not be accessed. For service contact your authorised stockist.
WARNING! Only a good quality Jack oil, such as SEALEY HYDRAULIC JACK OIL must be used.
7.6.
The hydraulic oil volume for the model is as follows: STL1000 : 2.0L STL600 :1.8L
DO NOT use brake fluid.
8
7.7.
Before each use, follow the pre-check list to ensure components are not damaged, broken, cracked, bent, malfunctioning, distorted,
worn or loose.
7.8.
Ensure there is no visible damage to welds. If any suspect item is found, remove the jack from service and take the necessary action
to remedy the problem.
DO NOT use the jack if you believe it to have been subjected to abnormal load or shock.
8
7.9.
Periodically check the pump piston and piston rod for signs of corrosion.
NOTE: NO RESPONSIBILITY IS ACCEPTED FOR INCORRECT USE OF THE JACK.
7.10.
No modifications shall be carried out which adversely affect the compliance of the jack with this standard.
7.11.
Hydraulic products are only repaired by local service agents. We have service/repair agents in all parts of the UK.
DO NOT Return the jack to us. Please telephone 01284 757500 to obtain the address and 'phone number of your local agent. If the jack
8
is under guarantee, please contact your local stockist.

8. TROUBLESHOOTING

8.1.
The jack cannot be lifted to the highest position: check and add hydraulic oil.
8.2.
Poor oil pump (empty pump): check whether the exhaust rod is pulled out.
8.3.
Lowering under load (not keeping pressure well): check whether the pressure relief knob is closed tightly.
ENVIRONMENT PROTECTION
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted,
taken to a recycling centre and disposed of in a manner which is compatible with the environment. When the product
becomes completely unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and
dispose of the product and fluids according to local regulations.
Note: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior
notice. Please note that other versions of this product are available. If you require documentation for alternative versions, please email or call
our technical team on technical@sealey.co.uk or 01284 757505.
Important: No Liability is accepted for incorrect use of this product.
Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim.
Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR
01284 757500
© Jack Sealey Limited
sales@sealey.co.uk
Original Language Version
www.sealey.co.uk
500TTJ.V3, 800TTJ.V2
Issue 1 02/10/23
REGISTER YOUR
PURCHASE HERE

Advertisement

loading

This manual is also suitable for:

800ttj.v2