7-4. ERROR DISPLAY
If you press the Start/Pause button in error condition, any error except
machine will change into the pause status.
In case of
,
error is not resolved within 4 min., the power will turn o ff automatically and the error only will blink.
But in the case of
ERROR
1
WATER INLET
ERROR
WATER OUTLET
2
ERROR
3
OVERFLOW
ERROR
4
PRESSURE SENSOR
S/W ERROR
5
DOOR OPEN
ERROR
6
UNBALANCE
ERROR
7
THERMISTOR(HEATING)
ERROR
, if the error is not resolved within 20 sec., and in case of all other errors, if the
, the power will not turn o ff.
SYMPTOM
CAUSE
Not reached the water level(248) within 10 minutes
after water supplied or not reached to the preset
water level within 25 minutes.
Not fully drained within 10 minutes.
Water is overflowing (under 21.3kHz).
If "
" is displayed, the drain pump operates
to drain the water automatically.
The pressure sensor switch is out of order.
In case of operating the reservation function or the
other function with door opened. Close the door,
then the error display is resolved.
The door switch is out of order.
The appliance is tilted.
Laundry is gatherd to one side.
The THERMISTOR is out of order.