Route the cables around the MA Board (assembly) and secure them with tape as given in the figure below.
1.
Secure the cables on the INT Duct (assembly) at two parts (1A/1B) with polyimide tape. (taping 1A is for EH-TW8000W/TW9000W only.)
2.
Secure the cables on the EX Duct (assembly) at two parts (2) with polyimide tape.
3.
Secure the SW Cable and PS Unit cable on the side of the INT Duct (assembly) at two parts with polyimide tape.
4.
Tuck the excess portion of the PS TH Cable under the MA Board (assembly) (4).
5.
Route the cables to the wiring gutter along the MA Fasten Plate (5).
6.
Route the GND Cable to the wiring gutter along the MA Fasten Plate (5) also.
PS TH Cable
SW Cable
3
4
PS TH Cable
SEIKO EPSON
Disassembly and Assembly
INT Duct
(assembly)
1B
1A
EX Duct
(assembly)
2
72
CONFIDENTIAL
MA Fasten Plate
5
GND Cable
Wiring gutter