Install Vent System - Whirlpool LDR3822 Use And Care Manual

120-volt electric compact dryer
Table of Contents

Advertisement

Available languages

Available languages

Special provisions for mobile home installations
The exhaust vent must be securely fastened to a noncombustible
portion of the mobile home structure and must not terminate
beneath the mobile home. Terminate the exhaust vent outside.
Determine vent length
1. Select the route that will provide the straightest and most
direct path outdoors. Plan the installation to use the fewest
number of elbows and turns. When using elbows or making
turns, allow as much room as possible. Bend vent gradually
to avoid kinking. Avoid 90° turns when possible.
better
2. Determine vent length.
The maximum length of the exhaust system depends upon:
The type of vent (rigid metal or flexible metal).
The number of elbows used.
Type of hood.
Recommended hood styles are shown here.
A
(102 mm)
A. Louvered style
B. Box hood style
good
B
4"
(102 mm)
4"
The angled hood style (shown following) is acceptable.
4"
(102 mm)
See the exhaust vent length chart that matches your hood type
for the maximum vent lengths you can use.
Exhaust systems longer than specified will:
Shorten the life of the dryer.
Reduce performance, resulting in longer drying times and
increased energy usage.
3. Determine the number of elbows you will need.
IMPORTANT: Do not use vent runs longer than specified in the
Vent Length Chart.
Find the maximum length of metal vent on the same line as the
number of elbows.
Vent Length Chart
Number of
Type of
90º turns
vent
or elbows
0
Rigid metal
1
Rigid metal
2
Rigid metal

Install Vent System

1. Before installing the vent system, be sure to remove the wire
exhaust guard that is located at the exhaust outlet.
2. Install exhaust hood. Use caulking compound to seal exterior
wall opening around exhaust hood.
3. Connect vent to exhaust hood. Vent must fit inside exhaust
hood. Secure vent to exhaust hood with 4" (102 mm) clamp.
4. Run vent to dryer location. Use the straightest path possible.
See "Determine vent length." Avoid 90º turns. Use clamps to
seal all joints. Do not use duct tape, screws, or other fastening
devices that extend into the interior of the vent to secure
the vent, because they can catch lint.
2½"
(64 mm)
Box or
Angled
louvered
hoods
hoods
36 ft (11 m)
26 ft (7.9 m)
26 ft (7.9 m)
16 ft (4.9 m)
16 ft (4.9 m)
6 ft (1.8 m)
7

Advertisement

Table of Contents
loading

Table of Contents