Remarks: The above are the maximum frequency limitations of the complete appliance which are
affected by the environment, and they have nothing to do with the ability of the indoor unit.
Refrigeration/dehumidification mode:
Serial No.
1
2
3
4
5
6
7
Remarks: the above are not only the maximum frequency limitations of the complete appliance
which are affected by the environment, but also the maximum ability limitation of the system. When the
starting ability is not the maximum, its maximum frequency limitation is calculated by the following
equations:
The frequency limitation which is affected by the temperature and under the condition of actual
ability the actual running system ability*the maximum frequency which is limited by the temperature
and under the condition of maximum ability/the maximum designing ability of the system
Refrigeration/dehumidification mode:
The indoor setting
airflow speed
The percentage of the
rated frequency K
(09K)
Heating mode:
The indoor setting
airflow speed
The percentage of the
rated frequency K
(09K)
The calculation of the actual output frequency:
F= F-ED-*(rated frequency) K
F-ED-*(rated frequency)= The frequency which is limited by the outdoor environment temperature
Notes:
When refrigerating, it is needed to satisfy
Wh_c<-2
Wh_c<4
Wh_c<10
Wh_c<17
Wh_c<20
Wh_c> 20
Temperature scope
Wh_c<16
Wh_c<22
Wh_c<29
Wh_c<32
Wh_c<40
Wh_c<48
Wh_c>=48
Low
70%
Low
80%
Max_hz3
109HZ
Max_hz4
102HZ
Max_hz5
91HZ
Max_hz6
79HZ
Max_hz7
69HZ
Max_hz8
59HZ
Frequency limitation 09K
Max_hz1
51HZ
Max_hz2
59HZ
Max_hz3
67HZ
Max_hz4
72HZ
Max_hz5
79HZ
Max_hz6
71HZ
Max_hz7
59HZ
Medium
85%
Medium
90%
Domestic air conditioner
16
Functions and control
Quiet
50%
Quiet
51%