Maintenance
Recommended Maintenance Schedule(s)
Maintenance Service
Interval
Every 100 hours
Engine Maintenance
Cleaning the Spark Arrester
Service Interval: Every 100 hours/Every 6 months
(whichever comes first)
1. Remove the muffler from the machine; refer to
Removing the Muffler Guards (page
2. Remove the spark arrester
3. Use a brush to carefully remove carbon deposits
from the spark-arrester screen
Note:
Replace the spark arrester if it has
breaks or holes.
1. Spark arrester
4. Install the spark arrester
Maintenance Procedure
• Clean the spark arrester.
1).
(Figure
4).
(Figure
5).
Figure 5
2. Brush
(Figure
4)