MONO OPERATION
With
the MONO switch depressed,
the Channel 1 input will feed both sides
of
the amp. Volume for both sides is controlled with the channel 1 LEVEL control.
IN
BRIDGING OPERATION
Ashly
amplifiers
are
in
ttie bridging mode when both the
MONO
switch
and
BRIDGING switch are depressed.
In this mode, the channel one input feeds both
sides of the amp,
but the phase of the channel two amplifier is inverted
180
degrees,
so
that the two amplifiers' outputs are out of phase.
The speaker
connection
is then made to the two RED output Jacks,
as shown in
Figure
8.
The black output jacks are not used.