Stereo Playback Monitoring System; Mono Operation In High Level Bi-Amped System - Ashly SRA-120 Operating Manual

Ashly operating manual power amplifier sra-120
Hide thumbs Also See for SRA-120:
Table of Contents

Advertisement

Operating Manual - SRA-120 Power Amplifier
8.2

Stereo Playback Monitoring System

Here the SRA-120 is fed from a low line-level (-10dBu) stereo tape machine or CD player. Only the sensitiv-
ity switch should be depressed.
8.3

Mono Operation in High Level Bi-Amped System

Here the SRA-120 is fed from the high frequency output of a professional two-way crossover. The stereo/
mono and normal/bridged switches are both depressed to obtain the maximum amount of power when amplifying a
mono signal. In this mode, the channel 1 input feeds both sides of the amp, but the phase of channel 1 is inverted so
the voltage difference between the channel 2 and channel 1 red binding posts is twice as great as either would be
relative to the black binding posts. The (+) in-phase speaker connection is then made to the channel 2 red binding post
and the (-) out of phase speaker connection is made to the channel 1 red binding post. (Warning: the output power
available to the horn or loudspeaker is doubled when in bridged/mono mode. Some horn drivers may be damaged by
excessive power.)
9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents