@ SEMI-BREAK-IN
OPERATION
The TS-830S
has a built-in side-tone
oscillator to permit
semi-break-in operation, besides the normal CW operation.
During
semi-break-in
operation,
the transceiver
is set in
transmit
mode
when
the key is depressed,
and returns to
receive mode when the key is released.
For semi-break-in
operation, place the STANDBY
switch to REC and turn the
VOX GAIN contro! ON.
Adjust the DELAY control for your
preference.
A fixed channel is available for common
use on all bands by
installing
a
crystal
in
the
socket
on
the
PLL
unit
(X50-1680-00).
The crystal frequency can be computed by
the following formula:
Crystal
Frequency
(MHz)
=
5.5 MHz
X +
Operating
Frequency
(MHz).
X =
Band
Switch
frequency
(1.5, 3.5, etc.)
Crystal specifications:
See Fig. 4-15
receive, and the RIT/XIT circuit are not effective in FIXED
'CHANNEL
OPERATION.
To use the fixed frequency oscillator, depress the FIX push
switch.
OC+9V
Q1, Q2 :2SC1815(Y)
1.8K
100P
* 0022
100
150
py
if
CRYSTAL SPECIFICATIONS
1. Type of holder: HC-25/u
I
2. Frequency:
5.5 ~ 6.0 MHz
3. Multiplication:
Fundamental
4. Tolerance:
0.002% (Normal temperature)
5. Capacitance
6. Loading
7. Correction factor
8. Drive level
Fig. 4-15
Crystal Oscillator Circuit
4.6
DIGITAL
DISPLAY
CALIBRATION
Connect the antenna
and set the BAND
switch to WWV.
Turn the main tuning dial to receive 10 MHz WWV.
Adjust
the dial until a low-frequency beat is heard.
Next, turn the
MIC control to the CAL position and a marker signal will be
superimposed
on the WWYV signal.
A double beat (two beat
signals of high and
low frequencies)
will now
be heard.
Adjust the IF shift for low AF response.
While receiving this double beat, adjust the Standard oscil-
lator trimmer through the reference frequency adjustment
access opening (on the bottom of the TS-830S) so the two
beats are heard as a single beat.
Repeat this procedure 2 or
3 times.
This completes calibration of the Digital Display.
After calibration turn of the CAL switch.
Access (STD.OSC. F.ADJ)
Insulated tuning tool
Fig. 4-16 Digital Display Calibration
4.7
ANALOG
DIAL CALIBRATION
The dial scale is graduated
at 1 kHz intervals.
One revo-
lution of the main dial covers 25 kHz. To calibrate the scale,
turn the MIC control to the CAL position.
Zero-beat in either
SSB or CW mode.
Hold the main tuning knob from rotating
and slip the clibration ring to the nearest
major (5 kHz)
graduation.
The dial is now calibrated.
NOTE:
For exact frequency,
read the Digital Display.
Pointer
Fig. 4-17 Analog Dial Calibration