5, Place MODE
switch to TUNE, METER
switch to ALC.
Peak the DRIVE control.
If the meter pegs or goes out
of the ALC range, reduce the CARRIER control setting
for an on-scale
reading.
(the CAR
control
is a level
adjustment,
while the DRIVE
control is a resonating
adjustment.)
NOTE:
-
The TUNE position permits tuning of the final tank circuit at
reduced power without danger to the tubes.
In the TUNE
position,
the
screen
voltage
to
the
finals
is
reduced
approximately
50% and the keying circuit is closed.
Adjust
DRIVE
control for
maximum
on-scale meter deflection.
METER
669 x)
HF TRANSCEIVER
Fig. 4-10 Peaking the DRIVE control
6. Place the meter switch to IP and dip the PLATE.
Dip
will be typically only aout 5ma.
(or to RF and peak the
plate.)
Mic-BecaR
My Seer
cH
VETS rove HEATER PoweR
cecan
EY
Cy Serpe nore
var
rove
Quickly adjust the PLATE control and
then the LOAD control alternately to
peak (maximum meter deflection) power output.
For maximum.
deflection
HF TRANSCEIVER
Fig. 4-12
Final Tuning
7. Place the meter switch to RF and peak the LOAD
control
8. Place the Mode
switch to CW,
Meter switch
to Ip.
Close
the key and
IMMEDIATELY
redip the
PLATE
control.
Reduce the carrier contr-| setting if Ip reads
over 265ma.
Open the key.
9. Place the meter switch to RF.
Close the key and repeak the LOAD for maximum
RF
output.
You may at your option also redip the PLATE
for maximum
RF output.
Open the key.
You are tuned up for CW operation.
If
necessary, adjust the RF METER control on the rear pa-
nel to bring the output reading to about 2/3 scale.
This is a meter adjustment, not an output adjustment.
NOTE:
Dip point may not always coincide with maximum output,
because
neutralization
is accomplished
on the
10 meter
band.
For this reason, you may simply adjust both the PLATE and
the LOAD controls for maximum output as described in both
tune-up procedure and summary
Table 4-1.
Peale o a
HF TRANSCEIVER
i,
Adjusting point
Adjust PLATE control for dip.
|
RF
Fig. 4-11
Plate Adjustment
py ate aajistmenbrange
Table 4-1.
Summary of Transmitter Tuning Procedure
MODE Switch
METER Switch
Stand-by Switch
Procedure
USB or LSB
IP
TUNE
ALC
TUNE
IP
TUNE
RF
CW
RF
REC
SEND
REC—
SEND
REC
SEND
REC
SEND
REC— SEND
Adjust BIAS control for 60 ma.
Peak the ALC reading with the DRIVE control.
DIP the PLATE reading with the PLATE control.
PEAK RF Reading with the load control.
Peak RF output by alternately adjusting the
PLATE and LOAD controls.

Advertisement