Kenwood TS-670 Instruction Manual page 32

All mode quad bander
Hide thumbs Also See for TS-670:
Table of Contents

Advertisement

==b5. TROUBLESHOOTING
agent or service station.
TRANSMISSION
SYMPTOM
CAUSE
REMEDY
No
output
in SSB
(RF
and
ALC
meters do not deflect.)
1. The MIC plug is incompletely inserted.
2. Low microphone gain.
. Insert the MIC plug fully.
. Increase the microphone gain.
No output in CW
1. The
KEY
plug is incompletely
inserted
or
KEY contact failure.
2. CAR control is too low.
. Insert the KEY plug fully.
- Turn the CAR control clockwise.
Nalya
RECEPTION
SYMPTOM
CAUSE
REMEDY
Indicators
do
not
light
and
no
receiver
noise
is heard
when
the
POWER switch is turned on.
1. Poor power cord connection with the con-
netor.
2. Blown power supply fuse.
3. PS-20 is OFF.
. Make correct connection.
. Replace the fuse.
(If the new fuse blows
again, the set is defective.)
3. Set PS-20 to ON.
N=
Nothing is displayed or wrong digits
are
displayed
when
the
POWER
switch is turned on.
The microprocessor malfunctions. This occurs
when the battery is old or the supply voltage
drops extremely on the occasion of consum-
ing large current.
. Adjust
the
supply
voltage
to
nominal
voltage
+10V
with use
of a boosting
transformer (in the case of using PS-20).
Use a 12 —
16 V battery.
2. Turn the POWER switch on again.
No signal is received even when the
antenna is connected.
. Squelch control works.
. Microphone PTT switch is in the transmit
position, and the TS-670 is in the transmit
mode.
ror
1. Turn
the
squelch
control
wise.
2. Set the PTT switch to the receive position.
counterclock-
An antenna
is connected,
but no
signal is received
and the S-meter
fully deflects.
RF control is too low, decreasing the high fre-
quency circuit gain.
Turn the RF control fully clockwise.
The S-meter deflects and stays at a
certain position even with no signal.
1. Too low supply voltage.
2. RF control is too low.
1. Adjust
the
supply
voltage
to
nominal
voltage
+10V
with
use
of a boosting
transformer (in the case of using PS-20).
Use a 12 —
16 V battery.
2. Turn the RF control fully clockwise.
Signal is received,
but no sound is
heard.
MODE switch position is incorrect.
}
Change the MODE switch position.
SSB
received
signal
is extremely
high cut or low cut.
IF shift control is wrongly adjusted.
Set the control to the center (click position).
Frequency is not changed by press-
ing the BAND switch or turning the
tuning control.
1.
LOCK
switch is ON.
2.
VFO/M
is ON.
1. Set LOCK
switch to OFF.
2. Set VFO/M
to OFF.
Scan fails.
1.
HOLD
switch is ON.
2. Memory is empty.
3. Frequencies
entered
in channels
8 and 9
exceed the limit.
Set HOLD
switch to OFF.
Store data in the memory.
Re-enter the frequencies within the limit.
ON
Display goes out with
VFO/M
ON.
When nothing is stored in the memory chan-
nel, a channel
is displayed and blanked
with
only the decimal point displayed.
Store the frequency.
30

Advertisement

Table of Contents
loading