Table of Contents

Advertisement

Quick Links

SDL3 Converter
User's manual
Version: 2.01 (November 2022)
Order no.: MASDL3CON-ENG
Translation of the original documentation

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SDL3 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for B&R SDL3

  • Page 1 SDL3 Converter User's manual Version: 2.01 (November 2022) Order no.: MASDL3CON-ENG Translation of the original documentation...
  • Page 2 Publishing information B&R Industrial Automation GmbH B&R Strasse 1 5142 Eggelsberg Austria Telephone: +43 7748 6586-0 Fax: +43 7748 6586-26 office@br-automation.com Disclaimer All information in this document is current as of its creation. The contents of this document are subject to change without notice.
  • Page 3: Table Of Contents

    3.1 Information about this user's manual......................11 3.2 SDL3 Converter for Automation PCs......................11 3.3 Connection options............................12 3.3.1 SDL3 operation............................12 3.3.1.1 SDL3 operation with SDL3 Converter via SDL................. 12 3.3.1.2 SDL3 operation with SDL3 Converter via DVI.................. 14 3.3.2 General limitations/characteristics......................14 3.4 Design/Configuration............................. 15 3.5 System data..............................
  • Page 4 6 Commissioning......................34 6.1 Basic information............................34 6.2 Switching on the device for the first time..................... 34 6.2.1 General information before switching on the device................34 6.2.2 Switching on the SDL3 Converter......................34 7 Software........................35 7.1 Upgrade information............................35 7.1.1 Firmware upgrade........................... 35 8 Maintenance......................36 8.1 Repairs/Complaints and replacement parts....................36...
  • Page 5: Introduction

    "Cable strain relief clip 5ACCRHMI.0011-000" on page 41 ° "General accessories" on page 39 1.00 2015-04-15 • Updated technical data for the 5COSD3.1000-00 SDL3 Converter, see "Technical data" on page • Updated section "Grounding concept" on page • Updated figures for the SDL3 Converter.
  • Page 6: Guidelines

    Up to 6 mm ±0.1 mm Over 6 to 30 mm ±0.2 mm Over 30 to 120 mm ±0.3 mm Over 120 to 400 mm ±0.5 mm Over 400 to 1000 mm ±0.8 mm SDL3 Converter User's manual V 2.01...
  • Page 7: General Safety Guidelines

    Are protected by ESD-suitable packaging. 2.2.2 Regulations for proper ESD handling Electrical assemblies with housing • Do not touch the connector contacts of connected cables. • Do not touch the contact tips on circuit boards. SDL3 Converter User's manual V 2.01...
  • Page 8: Regulations And Measures

    • General safety regulations and national accident prevention regulations must be observed. • The electrical installation must be carried out in accordance with relevant regulations (e.g. line cross section, fuse protection, protective ground connection). SDL3 Converter User's manual V 2.01...
  • Page 9: Operation

    Internet poses a potential threat to the system. It is the direct responsibility of the user to avert these dangers and to take appropriate measures such as virus protection programs and firewalls to protect against them and to use only software from trustworthy sources. SDL3 Converter User's manual V 2.01...
  • Page 10: Cybersecurity Disclaimer For Products

    The term "control systems" refers to all types of B&R products such as controllers (e.g. X20), HMI systems (e.g. Power Panel T30), process control systems (e.g. APROL) and supporting systems such as engineering workstations with Automation Studio. SDL3 Converter User's manual V 2.01...
  • Page 11: System Overview

    3 System overview 3.1 Information about this user's manual This user's manual contains all necessary information regarding the SDL3 Converter. For information about SDL3 link modules and SDL3 transmitters, see the Automation Panel and Automation PC user's manuals. Information: All specifications in dimension diagrams and associated tables are in millimeters [mm].
  • Page 12: Connection Options

    Operation with a USB type A/B cable The Automation Panel can be up to 100 m away from the SDL3 Converter; USB 2.0 is fully integrated in the SDL3 transfer and transferred over this distance. The maximum distance for transferring data between the B&R industrial PC and SDL3 Converter (5COSD3.1000-00) is 5 m;...
  • Page 13 Operation without a USB type A/B cable The Automation Panel can be up to 100 m away from the SDL3 Converter; USB 2.0 is fully integrated in the SDL3 transfer and transferred over this distance. The maximum distance for transferring data between the B&R industrial PC and SDL3 Converter is 10 m;...
  • Page 14: Sdl3 Operation With Sdl3 Converter Via Dvi

    USB type A/B cable. The Automation Panel can be up to 100 m away from the SDL3 Converter; USB 2.0 is fully integrated in the SDL3 transfer and transferred over this distance. The maximum distance for transferring data between the B&R industrial PC and SDL3 Converter is 5 m;...
  • Page 15: Design/Configuration

    Terminal blocks Select 1 Power supply connector 0TB103.9 0TB103.91 Accessories Optional selection Cable strain relief clip 5ACCRHMI.0011-000 Only required for SDL operation. Only required for DVI operation. Optional for SDL operation, required for DVI operation. SDL3 Converter User's manual V 2.01...
  • Page 16: System Data

    The SDL3 Converter makes operation via SDL3 with B&R industrial PCs and Automation Panels possible that are not equipped with an SDL3 interface or SDL3 slot. Upgrading systems to SDL3 in the course of retrofitting or modifications is extremely easy. When combined with an SDL3 interface integrated on a B&R industrial PC, two Automation Panels can be connected in dual-independent display mode.
  • Page 17: Technical Data

    500 m above sea level. Top-hat rail clamp set X20AC0RF1 can also be used for improved installation / vibration resistance. Vibration testing is performed per EN 60068-2-6. Shock testing is performed per EN 60068-2-27. SDL3 Converter User's manual V 2.01...
  • Page 18: Dimensions

    System overview 3.5.1.4 Dimensions Information: All specifications in dimension diagrams and associated tables are in millimeters [mm]. 2D and 3D diagrams (DXF and STEP formats) can be downloaded from the B&R website (www.br-automation.com). SDL3 Converter User's manual V 2.01...
  • Page 19: Device Interfaces

    "LED status indicators" on page 22 "+24 VDC power supply" on page 20 "SDL/DVI In interface" on page 21 "Grounding" on page 20 "USB In interface" on page 22 "SDL3 Out interface" on page 22 SDL3 Converter User's manual V 2.01...
  • Page 20 For example, a copper strip must be attached to the ground connection at a central grounding point of the control cabinet or system in which the device is installed. The wire cross section should be as large as possible (at least 2.5 mm²). SDL3 Converter User's manual V 2.01...
  • Page 21 1920 x 1080 5CADVI.0018-00 5CADVI.0018-00 5CADVI.0018-00 5CADVI.0018-00 5CADVI.0018-00 5CADVI.0018-00 5CADVI.0018-00 5CADVI.0050-00 5CADVI.0050-00 5CADVI.0050-00 5CADVI.0050-00 5CADVI.0050-00 5CADVI.0050-00 5CADVI.0050-00 The maximum cable length for DVI transfer is limited to 5 m due to the USB specification. SDL3 Converter User's manual V 2.01...
  • Page 22 Recalibration may be required for touch screen de- vices. A maximum of 500 mating cycles are specified for this interface. 3.5.2.1.4 LED status indicators LED status indicators are located on the front of the SDL3 Converter. Assignment Color Status...
  • Page 23: Overview

    Connector 24 VDC - 3-pin, female - Screw clamp terminal block 3.31 mm² 0TB103.91 Connector 24 VDC - 3-pin, female - Cage clamp terminal block 3.31 mm² 5ACCRHMI.0011-000 Strain relief USB - For APC2100/APC2200 - For SDL3 Converter/SDL4 Converter Converter 5COSD3.1000-00 SDL/SDL3 Converter Other 5ACCRHMI.0006-000...
  • Page 24: Dimensioning

    ≥ 50 ≥ 100 ≥ 50 Caution! The specified spacing for air circulation is based on worst-case operation at the maximum specified ambient temperature. The maximum specified ambient temperature is not permitted to be exceeded! SDL3 Converter User's manual V 2.01...
  • Page 25: Installation And Wiring

    If the load-bearing capacity of the mounting surface is insufficient, or if the fastening material is inadequate or incorrect, the device may fall and become damaged. • To avoid overheating, the device is not permitted to be placed near other heat sources. SDL3 Converter User's manual V 2.01...
  • Page 26 If third-party devices or components are used, the relevant manufacturer's documentation must be observed. If lim- itations or interactions by or with third-party products are possible, this must be taken into account in the application. SDL3 Converter User's manual V 2.01...
  • Page 27: Installing The Sdl3 Converter

    EN 50022 standard. 5.2.1 Procedure 1. Attach the SDL3 Converter in the desired position to the top-hat rail (1) and press down (2) on the device to engage the locking mechanism (3). SDL3 Converter User's manual V 2.01...
  • Page 28: Installing The Cable Strain Relief Clip

    Installation and wiring 5.3 Installing the cable strain relief clip 1. The cable strain relief clip must be positioned on the SDL3 Converter according to the following figure and secured with the supplied locating screws (M3, max. tightening torque 0.5 Nm).
  • Page 29: Connecting To The Power Grid

    ③ as shown in the figure below. Close the terminal contact by removing the screwdriver. It is important to pay attention to the label on the cage clamp terminal ④. 24 VDC 0 VDC SDL3 Converter User's manual V 2.01...
  • Page 30: Connecting The Power Supply To A B&R Device

    (e.g. power supply unit). 1. Carry out electrostatic discharge on the housing or at the ground connection. 2. Connect the power supply connector to the B&R device and tighten the mounting screws (max. tightening torque 0.5 Nm). SDL3 Converter User's manual V 2.01...
  • Page 31: Grounding Concept

    On the 5COSD3.1000-00, the grounding and power supply connections are located on the underside of the device. Legend Power supply connection +24 VDC pin 2 Central grounding point Ground connection At least 1.5 mm² At least 2.5 mm² SDL3 Converter User's manual V 2.01...
  • Page 32: Connecting Cables

    When connecting or installing cables, the bend radius specification must be observed. For this specification, see the technical data of the respective cable. The maximum tightening torque of the locating screws is 0.5 Nm. Bend radius Locating screws SDL3 Converter User's manual V 2.01...
  • Page 33: Removing The Sdl3 Converter

    5.6 Removing the SDL3 Converter 5.6.1 Procedure 1. Pull the SDL3 Converter downwards (1) and slightly in the opposite direction away from the top-hat rail (2). This releases the locking mechanism for the top-hat rail installation. SDL3 Converter User's manual V 2.01...
  • Page 34: Commissioning

    • All connection cables are connected correctly. • An Automation PC or Panel PC and Automation Panel are connected. 6.2.2 Switching on the SDL3 Converter Procedure 1. Connect the power supply and switch it on.
  • Page 35: Software

    To upgrade the firmware, an APC3100, APC2200, APC2100, APC910 or PPC3100 or PPC900 with compatible MTCX firmware must be connected in addition to an Automation Panel with an SDL3 link module. A current firmware upgrade can be downloaded directly from the Downloads section of the B&R website (www.br-automation.com).
  • Page 36: Maintenance

    Repairs are therefore only permitted to be carried out by authorized qualified personnel at the manufacturer's premises. To process a repair/complaint, a repair order or complaint must be created via the B&R Material Return Portal on the B&R website (www.br-automation.com). SDL3 Converter User's manual V 2.01...
  • Page 37: International And National Certifications

    Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission stan- dard for industrial environments Information: Declarations of conformity are available on the B&R website under Downloads > Certificates > Decla- rations of conformity. SDL3 Converter User's manual V 2.01...
  • Page 38: Certifications

    Products with this marking are permitted to be imported into Great Britain (England, Wales, Scotland). Information: The declarations of conformity are available on the B&R website (Down- loads > Certificates > Declarations of conformity). SDL3 Converter User's manual V 2.01...
  • Page 39: Accessories

    Description 5ACCRHMI.0000-000 REP HMI grounding clip 5ACCRHMI.0011-000 REP strain relief USB - For APC2100/APC2200 - For SDL3 Converter/SDL4 Converter 10.2 Installation accessories Suitable tool sets can be ordered to easily install B&R industrial PCs and converters. • Consisting of: 5ACCRHMI.0006-000 °...
  • Page 40: 0Tb103.9X

    Yes, but applies only if all components installed in the complete system have this certification and are listed on the associated DNV certificate for the product family. The cage clamp terminal block cannot be used side by side. The respective limit data of the I/O modules must be taken into account! SDL3 Converter User's manual V 2.01...
  • Page 41: Cable Strain Relief Clip

    10.4 Cable strain relief clip 10.4.1 5ACCRHMI.0011-000 10.4.1.1 General information A cable strain relief clip is available for the SDL3 Converter. The locating screws and cable ties required for installation on the device are included in delivery. For details about installation, see "Installing the cable strain relief clip"...
  • Page 42: Environmentally Friendly Disposal

    Electronics recycling Operating and monitoring devices Uninterruptible power supplies Batteries and rechargeable batteries Cables Paper/Cardboard packaging Paper/Cardboard recycling Plastic packaging material Plastic recycling Disposal must be carried out in accordance with applicable legal regulations. SDL3 Converter User's manual V 2.01...

Table of Contents