Setting The Dip Switches; Dip Switch 1 (Set Of 6 Switches) - Navien NHB H Series Installation And Operation Manual

Table of Contents

Advertisement

6. Setting the DIP Switches

WARNING
Do not remove the front cover unless the power to the boiler is turned off or disconnected. Failure to
do so may result in electric shock.
Configure only the DIP switches that require adjustment according to the instructions in this manual. Do
not adjust any other DIP switches.
Ensure that the High Altitude setting reflects the actual location of the boiler. If not, it may cause personal
injury or malfunction of the boiler.
The boiler has 2 sets of DIP switches on the main circuit board (PCB). DIP switches are used to control the
functionality of the boiler. Set the DIP switches appropriately, based on the installation environment.

6.1 DIP Switch 1 (Set of 6 Switches)

The DIP SW1 (Set of 6 Switches) on the circuit board configures the operation status and model settings.
Switch
Function
1 & 2
Operation Status
5 & 6
Model Setting
O
O
N
N
1
2
3
4
5
6
1
2
Setting
Normal Operation
2-stage MAX
1-stage MIN
1-stage MAX
NHB-055H
NHB-080H
NHB-110H
NHB-150H
3
4
5
6
7
8
1-OFF, 2-OFF
1-ON, 2-OFF
1-OFF, 2-ON
1-ON, 2-ON
5-OFF, 6-OFF
5-ON, 6-OFF
5-OFF, 6-ON
5-ON, 6-ON
Setting the DIP Switches
67

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nhb-055hNhb-080hNhb-110hNhb-150hNhb-h series

Table of Contents