IV. INSTALLATION
L SERIES - INTERNAL
Drill
/
" hole through the bin wall or mounting surface at the center of each Bin-Flo aerator location. Insert the
7
16
tank nipple (short tapered thread end) in the aerator and place the unit inside the bin, inserting the tank nipple
through the drilled hole in the bin wall.
Place the gasket on the nipple next to the outside of the bin wall together with sufficient space wahsers and
lock securely in place with the locknut.
Install piping to the Bin-Flo aerators and complete connection to the air supply.
LL SERIES - INTERNAL
Drill
/
" hole through the bin wall at the center of each Bin-Flo aerator location and proceed as above.
9
16
AIR SUPPLY PIPING
Piping of adequate size to carry the required volume of low pressure air must be provided to assure reliable
operation of the Bin-Flo aerator. As a general guide the following minimum pipe sizes should be used for
the manifolds to which the aerators are attached. In all cases the number of pipe fittings should be held to a
minimum.
L SERIES
Pipe Size
No. of Bin-Flo
Aerators
3/4" (19 mm)
1 - 5
1" (25.4 mm)
6 - 9
1
/
" (32 mm)
10 - 12
1
4
LL SERIES
Pipe Size
No. of Bin-Flo
Aerators
1" (25.4 mm)
1 - 5
1
/
" (32 mm)
6 - 8
1
4
1
/
" (38 mm)
9 - 11
1
2
4