HOW MANY BIN-FLO AERATORS PER ROW?
To determine the number of Bin-Flo aerators required for each row, measure the length of the sloping side of
the hopper on which the aerators are to be installed. Refer to the table below, select the model to be used
(L Series or LL Series) and the spacing of the units. Read down the column until the approximate length of slope
is reached. The number of aerators required is shown at the right.
Example: The 6'11" slope will require 6 model L aerators mounted on 15" centers.
Number of
L Series Mounted On
Aeration
Pads per
12" Centers
Row
2
1' 8" (50.8 cm)
3
2' 8" (81 cm)
4
3' 8" (112 cm)
5
4' 8" (142 cm)
6
5' 8" (173 cm)
7
6' 8" (203 cm)
8
7' 8" (234 cm)
9
8' 8" (264 cm)
10
9' 8" (295 cm)
CONICAL HOPPER
In a conical hopper four rows of Bin-Flo aerators,
located as shown, are normally required. The L
Series should be used in small cones as the smaller
aerator adapts better to the curved surface. To
prevent clogging of material in discharge pipe or
chute, install one row of aerators on the under side
of the slope as shown.
Bin-Flo Aerators
Air Supply
LL Series Mounted On
15" Centers
20" Centers
1' 11" (50.8 cm)
2' 8" (81 cm)
3' 2" (81 cm)
4' 4" (132 cm)
4' 5" (112 cm)
6' 0" (183 cm)
5' 8" (142 cm)
7' 8" (234 cm)
6' 11" (173 cm)
9' 4" (284 cm)
8' 2" (203 cm)
11' 0" (335 cm)
9' 5" (234 cm)
12' 8" (386 cm)
10' 8" (264 cm)
14' 4" (437 cm)
11' 11" (295 cm)
16' 0" (488 cm)
24" Centers
3' 0" (91 cm)
5' 0" (152 cm)
7' 0" (213 cm)
9' 0" (274 cm)
11' 0" (335 cm)
13' 0" (396 cm)
15' 0" (457 cm)
17' 0" (518 cm)
19' 0" (579 cm)
PYRAMIDAL HOPPER
In a pyramidal hopper, four rows of Bin-Flo aerators
centered on the sloping sides usually assures full
and uniform flow. For minimum retention of material
in the corners, an alternate location in the valleys
is suggested. To prevent clogging of material in
discharge pipe or chute, install one row of aerators
on the underside of the slope as shown.
Air Supply
6
www.bindicator.com
Bin-Flo Aerators
Alternate Locations