Gallagher SMB USA Base Kit Installation Note Gallagher SMB USA Base Kit, T11 White Reader: C500306 Gallagher SMB USA Base Kit, T11 Black Reader: C500307 Gallagher SMB USA Base Kit, T15 White Reader: C500308 Gallagher SMB USA Base Kit, T15 Black Reader: C500309...
Introduction Thank you for choosing Gallagher. The Gallagher SMB security solution has been designed to meet the security needs for small to medium businesses. It is a fully integrated cloud-based security system that offers intruder alarm, access control, monitoring and user management all within one mobile app.
Page 3
What's connected? The hardware within the kit is pre-wired to support the site's default software configuration. OUT 5 OUT 6 IN 16 IN 15 IN 14 IN 13 Controller Secondary 8In 4Out Board Mains coming into the cabinet IN 12 IN 11 Primary IN 10...
Installation The installation of this kit must be carried out by a Gallagher SMB Partner. Follow the instructions in this document to install the kit. ATTENTION: This equipment contains components that can be damaged by electrostatic discharge. Ensure both you and the equipment are earthed before beginning any servicing.
Page 5
and a rear tamper sticker on the wall to detect a change in light when the cabinet is removed from the wall. • Locking the cabinet Two cabinet keys are provided to secure the contents of the cabinet. • Knockouts The knockouts in the side panels of the cabinet can be carefully tapped or cut out.
Page 6
2. Install readers The default configuration provides allocation for one reader. It is recommended at least one reader be configured to a site. This allows a user to arm or disarm locally using their smartphone, in the event that the site losses internet connectivity. The smartphone uses Bluetooth to communicate with the reader.
No. 6 pan head screw Bezel Building cable No. 6 pan head screw Building cable Reader tail Facia Connection Fit screw to secure facia to bezel 3. Connect inputs and outputs Two 8In 4Out Boards are pre-installed in the cabinet. The Primary board is directly below the controller.
Relays are provided as ‘dry’ contacts or ‘electromagnetically switched’ contacts. Each relay is rated 3 Amps at 24 Vdc for a resistive load, or 1 A at 24 Vdc for an inductive load. The relay is controlled by the assigned output in the SMB Configuration App.
Page 9
LifeSafety FPO150 The AC mains connection to the LifeSafety’s FPO150 power supply must be followed in accordance with LifeSafety’s installation manuals. All AC mains electrical connections must comply to the local electrical authority’s codes and NFPA section 70. Installation & service should be performed by a qualified service personnel.
Page 10
Note: Both Battery Low alarm and Mains Failure alarm are sent as a system notification to the customer via the Gallagher SMB app. These events are also visible in the Event History of the controller in the SMB Configuration app.
Page 11
The controller will restart after the download. Configuration changes should not be published to the controller at this time. The Gallagher SMB solution only supports the latest firmware version on the controller. The firmware version can be viewed within the Properties section of the Controller lightbox in the SMB Configuration app.
Page 12
The key account holder will be the first person from your customer’s site to download the Gallagher SMB App. The Key Account holder performs a similar role to a facility manager and is the person who will invite other users to the site.
Page 13
5. Enter cloud for the username, then GGLcloud for the password and press Enter. The Gallagher Cloud Controller Configuration web page displays. 6. Select the required link to configure the Controller as needed. 7. When finished, set DIP switch 1 to OFF.
Page 14
8. Configure the site Configure the site using the SMB Configuration App. Configure Areas, Inputs, Outputs, Doors, then click PUBLISH to download the configuration changes to the controller. For configuration instructions, refer to the Help Centre for Installers. 9. Test the site Test Mode allows technicians to install, configure, and test an SMB site without alarming others by setting off sirens or other devices activated in response to an alarm.
Page 15
The Key Account Holder will need to follow the instructions in the email to download the Gallagher SMB App and accept their credentials. Note: If you are unable to onboard the Key Account Holder, ensure they have a PIN or pattern set on their phone.
Page 17
T30 Keypad Reader: Height 118.0mm (4.65 in) Width 86.0 mm (3.39 in) Depth 26.7 mm (1.05 in) Maximum number of access controlled doors on one SMB controller Standards and compliance FCC, RCM, RoHS The reader is idle Maximum reader current during credential read Environmental protection and impact ratings are independently verified LifeSafety Power FP0150 https://www.lifesafetypower.com/docs/im_fpo.pdf...