Message Codes
The Active light will flash at ½ second intervals and then wait 2 seconds before repeating
the code. This will go on for approx 46 minutes and then simply turn off. Correct the
issue and perform a Test Dish. (See page 6)
The number of times the light flashes is the code.
Number of Flashes
2
Invalid Mode
3
Invalid Mode
4
Motor Time Out. No Counts. Elevation
5
Motor Time Out. No Counts. Azimuth
6
7
Limit ErrorElevation
8
Limit ErrorAzimuth
9
10
Tuner Failure
11
AGC Won't Lock
12
13
Main Sat. not found but some other Sat. found. Check for line of sight obstruction
14
15
16
No Satellites found
17*
Over Temperature 135 Degrees F
18
Dish did not raise high enough
19
Coax cables on backward
20
21
22
23
24
EEPROM Failure
25
AGC Control Failure
*Note: This pertains to the temperature within the electronic enclosure and is message is
provided as a warning when the temperature reaches a critical level for the Satellite
Receiver and not the Freedom Controller.
For any questions or comments please contact our
Technical Support Department at 18002477486.
Error Code
Operation and Installation Manual
Corrective Action
Check and correct DIP switch setting
Check and correct DIP switch setting
Check for shipping screws and cabling
Check for shipping screws and cabling
Check for shipping screws and cabling
Check for shipping screws and cabling
Call Technical Support
Call Technical Support
Check for line of sight obstruction
Receiver temp reaching critical level
Check elevation motor And run Test Dish
Reverse Coax on Freedom Controller
Call Technical Support
Call Technical Support