Message Codes - MotoSAT FREEDOM Operation And Installation Manual

Table of Contents

Advertisement

Message Codes 
The Active light will flash at ½ second intervals and then wait 2 seconds before repeating 
the code.  This will go on for approx 4­6 minutes and then simply turn off.  Correct the 
issue and perform a Test Dish. (See page 6) 
The number of times the light flashes is the code. 
Number of Flashes 
Invalid Mode 
Invalid Mode 
Motor Time Out. No Counts. Elevation 
Motor Time Out. No Counts. Azimuth 
Limit Error­Elevation 
Limit Error­Azimuth 
10 
Tuner Failure 
11 
AGC Won't Lock 
12
13 
Main Sat. not found but some other Sat. found. Check for line of sight obstruction 
14
15
16 
No Satellites found 
17* 
Over Temperature 135 Degrees F 
18 
Dish did not raise high enough 
19 
Coax cables on backward 
20
21
22
23
24 
EEPROM Failure 
25 
AGC Control Failure 
*Note: This pertains to the temperature within the electronic enclosure and is message is 
provided as a warning when the temperature reaches a critical level for the Satellite 
Receiver and not the Freedom Controller. 
For any questions or comments please contact our 
Technical Support Department at 1­800­247­7486.
Error Code 
Operation and Installation Manual 
Corrective Action 
Check and correct DIP switch setting 
Check and correct DIP switch setting 
Check for shipping screws and cabling 
Check for shipping screws and cabling 
Check for shipping screws and cabling 
Check for shipping screws and cabling 
Call Technical Support 
Call Technical Support 
Check for line of sight obstruction 
Receiver temp reaching critical level 
Check elevation motor And run Test Dish 
Reverse Coax on Freedom Controller 
Call Technical Support 
Call Technical Support 

Advertisement

Table of Contents
loading

Table of Contents