EMS EC-63-0001 Installation Manual page 2

Conventional interface card

Advertisement

6 Connection wiring continued
Option 1
Wired to provide fault
notification
on
the
conventional fire panel's
SOUNDER CIRCUIT
SOUNDERS
FAULT
EOL L1 L2
EOL L1 L2
(+) (-)
(+) (-)
(+) (-)
1
1
= Sounder circuit EOL resistor
2
= Alarm triggering resistor
3
= Zone circuit EOL resistor
LOOP IN
TX
RX
RESET
RADIO
-
+
POWER
FAULT
ISOLATE
WD
LOOP IN
-
LOOP OUT
-
Specification
Operating temperature
Storage temperature
Humidity
Supply
Current drawn from
connected panel (max.)
Voltage (max.)
IP rating
Dimensions (W x H x D)
Weight
Location
©2022 EMS Ltd. All rights reserved.
Zone interface monitor (ZIM)
LOGON
ANTENNA
KEEP CABLES AWAY FROM THIS AREA
SERIAL NO
with conventional interface
card (CIC) fitted
0
1
1
2
4
8
16
32
F-SAFE
64
CLOSED
LED
ENABLE
FAULT
INPUT 1 INPUT 2
EXPAN1
EXPAN2
OUTPUT 1
OUTPUT 2
IP- IP+ IP- IP+
3VDC SET RST
3VDC SET RST
N/O COM N/C
N/O COM N/C
SOUNDER
FAULT
ZONE
EOL L1 L2
EOL L1 L2
ALARM
EOL
L1 L2
RES
(+) (-)
(+) (-)
(+) (-)
(+) (-)
(+) (-)
(+) (-)
(+) (-)
ZONE/RESET
EOL
ALARM
RES
(+) (-)
(+) (-)
(+) (-)
2
3
Wireless
ON
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7
3V3
RX
TX
0V
zone monitor
HELP
BACK
(WZM)
+ -
SOUNDER
Conventional fire panel
-10 to +55 °C
5 to 30 °C
0 to 95% non-condensing
Powered from the zone interface monitor
6 mA
50 VDC
IP65
(when fitted inside zone interface monitor)
120 x 240 x 60 mm
0.95 kg
Type A: For indoor use
6 Connection wiring continued
Option 2
Wired to provide fault
notification
conventional fire panel's
ZONE CIRCUIT
SOUNDERS
L1 L2
EOL L1 L2
(+) (-)
(+) (-)
1
1
= Sounder circuit EOL resistor
2
= Zone circuit EOL resistor
3
= Alarm triggering resistor
LOOP IN
-
+
+ -
ZONE
Regulatory information
Manufacturer
Year of manufacture
Certification
Certification body
CPR DoP
Approved to
European Union
Directives
Page 2 of 2
Zone interface monitor (ZIM)
LOGON
ANTENNA
KEEP CABLES AWAY FROM THIS AREA
SERIAL NO
with conventional interface
on
the
card (CIC) fitted
0
1
1
2
4
8
16
32
F-SAFE
64
CLOSED
LED
ENABLE
FAULT
INPUT 1 INPUT 2
EXPAN1
EXPAN2
OUTPUT 1
OUTPUT 2
IP- IP+ IP- IP+
3VDC SET RST
3VDC SET RST
N/O COM N/C
N/O COM N/C
SOUNDER
FAULT
ZONE
EOL L1 L2
EOL L1 L2
ALARM
EOL
L1 L2
RES
(+) (-)
(+) (-)
(+) (-)
(+) (-)
(+) (-)
(+) (-)
(+) (-)
FAULT
EOL L1 L2
ALARM
RES
(+) (-)
(+) (-)
(+) (-)
(+) (-)
2
Wireless
ON
1 2 3 4 5 6 7 8
TX
RX
1 2 3 4 5 6 7
RESET
RADIO
3V3
RX
TX
0V
zone monitor
POWER
HELP
BACK
FAULT
ISOLATE
WD
(WZM)
LOOP IN
-
LOOP OUT
-
Conventional fire panel
Carrier Manufacturing Poland Sp. z o.o.
Ul. Kolejowa 24. 39-100 Ropczyce, Poland
See devices serial number label
14
0905
0359-CPR-00436
EN54-18:2005. Fire detection and fire alarm systems.
Part 18:Input/output devices.
EMS declares that this device is in compliance with Directive
2014/53/EU. The full text of the EU declaration of conformity
is available at the following internet address: www.
emsgroup.co.uk
2012/19/EU (WEEE directive): Products marked with this
symbol cannot be disposed of as unsorted municipal waste
in the European Union. For proper recycling, return this
product to your local supplier upon purchase of equivalent
new equipment, or dispose of it at designated collection
points. For more information see www.recyclethis.info
Dispose of your batteries in an environmentally friendly
manner according to your local regulations.
ZONE/RESET
EOL
L1 L2
(+) (-)
(+) (-)
3
+ -
+ -
SOUNDER
ZONE
TSD147-99 Issue 7 21/06/2022 AJM