XingKeChuang XKC-E700 Operating Instruction

Handheld liquid level detector

Advertisement

Quick Links

深圳市星科创科技有限公司
Shenzhen XingKeChuang Technology Co., Ltd.
XKC-E700-V1.6
Handheld liquid level detector
XKC-E700 operating instruction
Without putting it inside the container,
The height or position of the liquid can be detected outside the container。
xkc.com
Phone: 86-0755-33523599 FAX: 86-0755-33515410 URL: http://www.sz-
Address: Xinqiao Street Office, Baoan District, Shenzhen 11th Floor,
Dahong Science and Technology Park, Xinyu Road
Phone: 86-0755-33523599
FAX: 86-0755-33515410
URL: http://www.sz-xkc.com
Address: 11th Floor, No. 48, Xinyu Road, Xinqiao Community, Xinqiao Street, Baoan District, Shenzhen
1 / 9

Advertisement

Table of Contents
loading

Summary of Contents for XingKeChuang XKC-E700

  • Page 1 深圳市星科创科技有限公司 Shenzhen XingKeChuang Technology Co., Ltd. XKC-E700-V1.6 Handheld liquid level detector XKC-E700 operating instruction Without putting it inside the container, The height or position of the liquid can be detected outside the container。 xkc.com Phone: 86-0755-33523599 FAX: 86-0755-33515410 URL: http://www.sz-...
  • Page 2: Table Of Contents

    深圳市星科创科技有限公司 Shenzhen XingKeChuang Technology Co., Ltd. Table of Contents 1st. Overview ................................ 2 2nd.Product Features ............................2 3rd.Product Applications ............................ 3 4th.Scope of application ............................3 5th.Product parameter ............................3 6th.Application conditions ..........................4 7th.Product structure and function diagram..................... 4 8th.Function and usage ............................
  • Page 3: 3Rd.product Applications

    深圳市星科创科技有限公司 Shenzhen XingKeChuang Technology Co., Ltd. 6. Strong compatibility, penetrating various non-metallic containers, such as plastic, glass, ceramic and other containers, the sensing distance (container wall thickness) can reach 40mm; liquid, powder, and particulate matter can be detected. 7. Powered by 2 AAA batteries, the battery is cheap and easy to buy, with a NPN output at the end, suitable for docking with various devices to improve product flexibility.
  • Page 4: 6Th.application Conditions

    深圳市星科创科技有限公司 Shenzhen XingKeChuang Technology Co., Ltd. Induction thickness (sensitivity) range ≤40mm (container wall thickness) Liquid level error ± 3mm 1PIN (empty pin) 2PIN (OUT) 3PIN(GND) 4PIN(empty Terminal definition pin) Display mode digital tube Material ABS-V0 level(fireproof material) Safety standard certification Environmental certification ROHS-2.0...
  • Page 5: 8Th.function And Usage

    深圳市星科创科技有限公司 Shenzhen XingKeChuang Technology Co., Ltd. 8th.Function and usage 1. On/off button: If it is not turned on, press and hold the “On/Off button” to display the sensitivity value; if it is turned on, press and hold the “On/Off button” to shut down.
  • Page 6: 10Th.use Environment

    深圳市星科创科技有限公司 Shenzhen XingKeChuang Technology Co., Ltd. Step 1: Long press the power button to start the hand-held liquid level detector. Adjust the sensor sensitivity value. (Refer to the following "Wall thickness and sensitivity") Step 2: Put the sensing surface of the hand-held liquid level detector close to the container wall and from the top Sliding to Down.
  • Page 7: 11Th.external Wiring Port Definition

    深圳市星科创科技有限公司 Shenzhen XingKeChuang Technology Co., Ltd. 3. Tank type: spherical tank, horizontal tank, vertical tank, etc. 11th.External wiring port definition 12th.Product precautions 1. Pay attention to keeping the level gauge clean, try to prevent corrosion and avoid violent collisions and blows from other objects.
  • Page 8 DOA application deadline is 7 days from the product shipment date. (F). Statement 1. The copyright of this manual belongs to Shenzhen Xingkechuang Technology Co., Ltd. (Xingkechuang) and its authorized licensors. Shenzhen Xingkechuang Technology Co., Ltd. (Xingkechuang) reserves all rights.
  • Page 9: 15Th. Manual Version

    4. Due to product version upgrades or other reasons, the contents of this manual may change. Xingkechuang reserves the right to modify the contents of this manual without any notice or prompt. This manual is only used as a guide.

Table of Contents