3. COMMISSIONING

3.1

Connecting the battery

As explained in chapter 2.3, it is important to first connect the battery to the solar charger by placing
the battery fuse or close the circuit breaker. When the battery is connected, the solar charger will
automatically detect the battery's nominal voltage. After this, the battery status and battery type
LEDs will be lit.
The battery status LED globally indicates the battery's condition. It can light in the following colors:
Battery status LED color
Green
Yellow
Red
The battery type LED indicates the selected battery type and its corresponding charge program. The
factory default battery type setting is 'AGM (sealed)' which corresponds to a green battery type LED.
The following alternative battery types are available:
Battery type LED color
Red
Yellow
Green
Blue
Purple
Orange
Cyan
White
1)
For lead based batteries, the nominal voltage will be detected automatically
2)
For LiFePo4 batteries, the nominal voltage has to be selected manually
3)
The factory default parameters for the 'Custom' battery type are the same as the 'AGM
(Sealed)' battery type
Indicator mode
Battery status
Continuous
Battery full
Continuous
Battery normal
Continuous
Battery voltage below undervoltage alarm
value
Quickly flashing
Battery undervoltage, overvoltage or
overtemperature alarm
Selected battery type
Flooded (FLD)
GEL
AGM (SLD)
LiFePo4 (12V)
LiFePo4 (24V)
LiFePo4 (36V)
LiFePo4 (48V)
Custom (user programmable)