Installation and Operating Instructions Davey Everyday Series E1P - E3P (XJ50P/XJ70P/XJ90P) Pressure Pumps & XJ50/XJ70/XJ90 Electric Pumps NOTE: Prior to installation remove the inlet and outlet pipe transport plugs & associated seals from the suction and/or discharge ports. Please pass these instructions on to the operator of this equipment.
Operating Instructions. Read these in their entirety before switching on this pump. If you are uncertain as to any of these Installation and Operating Instructions please contact your Davey dealer or the appropriate Davey office as listed on the back of this document.
Page 3
Housing your Davey Pressure System To protect your pressure system from the weather, make sure the pump house is both water proof, frost free and has adequate ventilation. The pump should be horizontally mounted on a firm base allowing for drainage, to avoid damage to flooring etc., that over time may occur from leaking...
Page 4
In most cases an isolating tank is required between mains supply and pump. Davey also recommend this method. Directly applied mains pressure can exceed pump operating pressure and damage pump.
Page 5
Connection to your Water Source BELOW GROUND WATER SOURCES Whenever the installation position of the pump is higher than 1m (3.3ft) above the lowest water level, a foot valve must be used on the end of the suction pipe as illustrated in (C) below.
Allow water to flow for 10-20 seconds to expel air then close outlet. Never operate your Davey Dynajet pump for more than a few ® seconds without discharge flow. Maintenance The only regular attention your new pressure system requires is to check the pressure tank’s air charge every 6 months.
4. Motor not free to turn eg. a jammed impeller. 5. Internal motor fault. *NOTE: For protection, the Davey pump motor is fitted with an automatic “over temperature” cut-out. Constant tripping of this overload device indicates a problem eg. low voltage at pump, excessive temperature (above 45 C) in pump enclosure.