Technical Information - PARRY AG2H Product Instructions

2 burner gas boiling hob
Table of Contents

Advertisement

Technical Information

Per Hob Burner
GAS
NATURAL G20
PROPANE G31
GAS RATE
M³/HR
NATURAL G20
0.588 M³/HR
PROPANE G31
0.178 M³/HR
AIR FLOW RATE FOR COMBUSTION
3
20m
/HR
BURNER LOW RATE
NATURAL G20
PROPANE G31
Total Unit
GAS
NATURAL G20
PROPANE G31
GAS RATE
M³/HR
NATURAL G20
1.176 M³/HR
PROPANE G31
0.356 M³/HR
AIR FLOW RATE FOR COMBUSTION
20m³/HR
BURNER LOW RATE
NATURAL G20
PROPANE G31
INJECTORS
Natural G20 = HOBINJECT 185
Propane G31 = HOBINJECT 105
IN101-6
OPERATING PRESSURE
20mb / 8" W.G.
37mb / 14.8" W.G.
FT³/HR
20.765 FT³/HR
6.286 FT³/HR
6.12 FT³/HR
FLOWRATE
0.126 M³/HR
0.029 M³/HR
OPERATING PRESSURE
20mb / 8" W.G.
37mb / 14.8" W.G.
FT³/HR
41.530 FT³/HR
12.572 FT³/HR
12.24FT³/HR
FLOWRATE
0.253 M³/HR
0.058 M³/HR
Parry-British Built for Purpose
TOTAL HEAT INPUT
5.557 KW = 18959 Btu/h
4.351 KW = 14846 Btu/h
LB/HR
KG/HR
0.691 LB/HR
0.313 KG/HR
HEAT INPUT
1.176 KW
0.700 KW
TOTAL HEAT INPUT
11.113 KW = 37918 Btu/h
8.702 KW = 29692 Btu/h
LB/HR
KG/HR
1.382 LB/HR
0.627 KG/HR
HEAT INPUT
2.357 KW
1.400 KW
14

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ag2hp

Table of Contents