  • Page 1 Instruction Manual AG4H / AG4HP 4 Burner Gas Boiling Hob...
  • Page 3: Table Of Contents

    Technical Information ....................... 16 Exploded View ........................... 17 Parts List ........................... 18 Warranty Information ......................19-20 Disposal & Recycling ......................... 21 Parry Catering Equipment (Midlands) Ltd, Town End Road, Draycott, Derby, DE72 3PT. Sales Tel: 01332 875544 Parry-British Built for Purpose IN268-2...
  • Page 4: Product Overview

    Product Overview The AG4H/AG4HP models are perfect for high volume catering, the Parry four-burner gas hobs are powerful and reliable. The precise adjustable thermostat controls make them responsive and precise while the high quality stainless steel construction ensures the units are both robust and easy to clean.
  • Page 5 GAS INPUT PRESSURE – Natural 20mbar GAS INPUT PRESSURE – Propane 37mbar GAS INPUT PRESSURE – Propane/Butane Can be converted using conversion kit? It leads the industry in: Design and aesthetic appeal Performance Power Functionality After sales support Parry-British Built for Purpose IN268-2...
  • Page 6: Safety Instructions

    To avoid scratching the highly polished exterior surface of this equipment whilst in transit, the protective film on the exterior surfaces has NOT been removed. It is IMPORTANT that this protective film is peeled off before the equipment is used. Parry-British Built for Purpose IN268-2...
  • Page 7: Installation Instructions

    Sides 150mm (6”) Hotplate to combustible material 1525mm (60”) All local fire regulations should be observed. It is recommended that the appliance be sited below a ventilating hood preferably of the extractor type incorporating a grease filter. Parry-British Built for Purpose IN268-2...
  • Page 8 All units should have a restraining cable fitted preventing the unit from being pulled away from the wall and causing the gas hose to become disconnected accidentally. Parry-British Built for Purpose IN268-2...
  • Page 9: Operating Instructions

    5. To turn burners off, turn knob clockwise all the way round. Parry recommends that the hob is used only with pans that have a minimum diameter of 120mm, and up to a maximum of 295mm diameter. This ensures that there is satisfactory combustion, and the pan is stable as it sits on the finger of the pan support.
  • Page 10: Maintenance Instructions

    SHOULD NOT BE ADJUSTED UNLESS BY A QUALIFIED ENGINEER IN WHICH CASE THE LOW RATE ADJUSTER SHOULD BE RE-SEALED. Parry recommends that this unit is serviced at least every 6 months As part of a full service we recommend the following checks are carried out.
  • Page 11: Replacement Parts

    Replacement Parts Parry Catering provides a complete after-sales service by offering the sales of spare parts directly to customers. Buying spares straight from the manufacturer allows customer to experience exceptional value and speedy delivery on all spare parts. For more information on buying spares visit: www.parry.co.uk/parry-commercial-catering-spares...
  • Page 12: Fault Finding

    Remake connection, reposition thermocouple-valve, incorrectly thermocouple located Burner goes out when turned Blockage in tap Clean and re-grease to “low” Irregular flame Burner ring/cap not correctly Relocate and check pressure at located, or low pressure test point. Parry-British Built for Purpose IN268-2...
  • Page 13: Nat Gas Conversion Instructions

    Hob valve NAT GAS Hob valve bypass COPBPS - 85 bypass screw screw stamped with 85 Hob burner NAT GAS Hob Burner HOBINJECT185 injector Injector stamped with 185 Labels NAT. GAS ONLY + G20 Instructions CONVIN23-4 Parry-British Built for Purpose IN268-2...
  • Page 14: Lpg Gas Conversion Instructions

    LPG Conversion Instructions Product AG4H – 4 Burner Gas Boiling Hob These instructions can be used for converting from Natural Gas to LPG LPG units are designed and tested in accordance with all current regulations enforced to run on the following gases only Propane G31 @ 37mbar 14.8”...
  • Page 15: Conversion Procedure

    Conversion Procedure Conversion Procedure for AG4H Warning Ensure the appliance is isolated from the gas supply before commencing conversion Remove pan supports and burner caps. Lift off aluminium burner plates. Remove the cover plate and solid top plates. Using an 10mm spanner remove burner injector.
  • Page 16 Connect the unit back to the gas supply. Test for gas soundness. Replace the facia and knobs accordingly When conversion is complete addix new data label and gas type label supplied with the conversion kit, detailing type of gas and pressure. Parry-British Built for Purpose IN268-2...
  • Page 17: Technical Information

    AIR FLOW RATE FOR COMBUSTION 24.48FT³/HR 20m³/HR BURNER LOW RATE FLOWRATE HEAT INPUT NATURAL G20 0.505 M³/HR 4.713 KW PROPANE G31 0.117 M³/HR 2.800 KW INJECTORS Natural G20 = HOBINJECT 185 Propane G31 = HOBINJECT 105 Parry-British Built for Purpose IN268-2...
  • Page 18: Technical Information

    This appliance should be routinely serviced to prolong its lifetime. Parry recommends that the appliance is serviced every 12 months by a Parry authorised engineer. Failure to service your product within the initial 12-month warranty period will cause the 24-month warranty to become void.
  • Page 19: Exploded View

    Exploded View Parry-British Built for Purpose IN268-2...
  • Page 20: Parts List

    COPRECI M14 x 1.5 NUT COPM14NUT GAS KNOB 5/16” DIA SHAFT ULYKNOB2 HOB GAS TAP PARAGON GASTAPHOB RANGE GAS RAIL FOR AG4H / AG4HP AG4HRAIL Saddle 09707409 SADDLEBKT Vinyl Round End Cap 26 mm PASCAP26MM ID 25mm Inside Height AEM Injector Carriage part of...
  • Page 21: Warranty Information

    Parry and not the sale or installation date of the equipment. Please ensure you have referred to the manufacturer’s instruction before placing a warranty...
  • Page 22 Faulty electrics – e.g. customer’s plug socket, plug, overuse of lava rock on chargrills. (Recommended wiring, junction box fault, wrong fuse. use by Parry no more than 2kg.) Products must be serviced within the first 12 Appliances that have been installed in mobile...
  • Page 23: Disposal & Recycling

    Disposal & Recycling The packaging should be disposed of in accordance with the regulations in force. Parry-British Built for Purpose IN268-2...