Product Overview The AG4H/AG4HP models are perfect for high volume catering, the Parry four-burner gas hobs are powerful and reliable. The precise adjustable thermostat controls make them responsive and precise while the high quality stainless steel construction ensures the units are both robust and easy to clean.
Page 5
GAS INPUT PRESSURE – Natural 20mbar GAS INPUT PRESSURE – Propane 37mbar GAS INPUT PRESSURE – Propane/Butane Can be converted using conversion kit? It leads the industry in: Design and aesthetic appeal Performance Power Functionality After sales support Parry-British Built for Purpose IN268-2...
To avoid scratching the highly polished exterior surface of this equipment whilst in transit, the protective film on the exterior surfaces has NOT been removed. It is IMPORTANT that this protective film is peeled off before the equipment is used. Parry-British Built for Purpose IN268-2...
Sides 150mm (6”) Hotplate to combustible material 1525mm (60”) All local fire regulations should be observed. It is recommended that the appliance be sited below a ventilating hood preferably of the extractor type incorporating a grease filter. Parry-British Built for Purpose IN268-2...
Page 8
All units should have a restraining cable fitted preventing the unit from being pulled away from the wall and causing the gas hose to become disconnected accidentally. Parry-British Built for Purpose IN268-2...
5. To turn burners off, turn knob clockwise all the way round. Parry recommends that the hob is used only with pans that have a minimum diameter of 120mm, and up to a maximum of 295mm diameter. This ensures that there is satisfactory combustion, and the pan is stable as it sits on the finger of the pan support.
SHOULD NOT BE ADJUSTED UNLESS BY A QUALIFIED ENGINEER IN WHICH CASE THE LOW RATE ADJUSTER SHOULD BE RE-SEALED. Parry recommends that this unit is serviced at least every 6 months As part of a full service we recommend the following checks are carried out.
Replacement Parts Parry Catering provides a complete after-sales service by offering the sales of spare parts directly to customers. Buying spares straight from the manufacturer allows customer to experience exceptional value and speedy delivery on all spare parts. For more information on buying spares visit: www.parry.co.uk/parry-commercial-catering-spares...
Remake connection, reposition thermocouple-valve, incorrectly thermocouple located Burner goes out when turned Blockage in tap Clean and re-grease to “low” Irregular flame Burner ring/cap not correctly Relocate and check pressure at located, or low pressure test point. Parry-British Built for Purpose IN268-2...
LPG Conversion Instructions Product AG4H – 4 Burner Gas Boiling Hob These instructions can be used for converting from Natural Gas to LPG LPG units are designed and tested in accordance with all current regulations enforced to run on the following gases only Propane G31 @ 37mbar 14.8”...
Conversion Procedure Conversion Procedure for AG4H Warning Ensure the appliance is isolated from the gas supply before commencing conversion Remove pan supports and burner caps. Lift off aluminium burner plates. Remove the cover plate and solid top plates. Using an 10mm spanner remove burner injector.
Page 16
Connect the unit back to the gas supply. Test for gas soundness. Replace the facia and knobs accordingly When conversion is complete addix new data label and gas type label supplied with the conversion kit, detailing type of gas and pressure. Parry-British Built for Purpose IN268-2...
This appliance should be routinely serviced to prolong its lifetime. Parry recommends that the appliance is serviced every 12 months by a Parry authorised engineer. Failure to service your product within the initial 12-month warranty period will cause the 24-month warranty to become void.
COPRECI M14 x 1.5 NUT COPM14NUT GAS KNOB 5/16” DIA SHAFT ULYKNOB2 HOB GAS TAP PARAGON GASTAPHOB RANGE GAS RAIL FOR AG4H / AG4HP AG4HRAIL Saddle 09707409 SADDLEBKT Vinyl Round End Cap 26 mm PASCAP26MM ID 25mm Inside Height AEM Injector Carriage part of...
Parry and not the sale or installation date of the equipment. Please ensure you have referred to the manufacturer’s instruction before placing a warranty...
Page 22
Faulty electrics – e.g. customer’s plug socket, plug, overuse of lava rock on chargrills. (Recommended wiring, junction box fault, wrong fuse. use by Parry no more than 2kg.) Products must be serviced within the first 12 Appliances that have been installed in mobile...
Need help?
Do you have a question about the AG4H and is the answer not in the manual?
Questions and answers