Establishing the exhaust air connection (exhaust
pipe, 120 mm diameter)
Secure the reducing connector to the air-pipe con-
1.
nector.
Secure the exhaust pipe to the air pipe connector.
2.
Establish the connection to the exhaust air opening.
3.
Seal the joints.
4.
Installing the flue duct
WARNING ‒ Risk of injury!
Components inside the appliance may have sharp
edges.
Wear protective gloves.
WARNING ‒ Risk of electric shock!
Sharp-edged components inside the appliance may
damage the connecting cable.
Do not kink or trap the connecting cable.
Screw the retaining bracket for the flue duct to the
1.
wall.
To separate the flue ducts, remove the adhesive
2.
tape or the flue duct from the protective packaging.
Remove any protective foil from both flue ducts.
3.
Use the 2 screws to screw the upper flue duct to
4.
the sides of the retaining bracket.
Note: To prevent scratches, lay soft towels over the
5.
edges of the outer flue duct to protect the surface.
Place the lower flue duct on the appliance and pull
it slightly apart.
Put the lower flue duct over the upper flue duct.
6.
Clip the lower flue duct onto the lower retaining
7.
bracket.
Ensure that the connecting cable is not trapped.
Carefully remove the towels.
8.