Chapter 5. Adjustment Procedure; After Replacement Of Any Pwb And/Or Ic For Repair, Note The Following; Software Updating - Sharp LC-26SA1E/RU Service Manual

Lcd colour television
Table of Contents

Advertisement

LC-26SA1E/RU, LC-32SA1E/RU
LC-26SA1E
CHAPTER 5.
ADJUSTMENT PROCEDURE
The adjustment values are set to their optimum at the factory before shipping.
If by any chance a value should become improper or a readjustment is required due to part replacement, make an adjustment according to the fol-
lowing procedure.

[1] After replacement of any PWB and/or IC for repair, note the following.

When replacing the following units, be sure to prepare the new units loaded with updated software.
MAIN-UNIT :
DUNTKD890FM12 (LC-26SA1E/K/F/I/RU)
DUNTKD890FM13 (LC-32SA1E/K/F/I/RU)
Note that an IC into which ROM data is written is available for MAIN-UNIT servicing (see below)
IC1901
VHi24LC2BiNEES
IC2303
RH-iXB731WJZZS EDID(PC)

[2] SOFTWARE UPDATING

There are 3 methods to update software in the VCTp: I2C method, RS-232C HyperTerminal and RS-232C Tera Term method.
RS-232C method is allowed when the TV is working properly and the action should be only software upgrade.
I2C method is required when the VCTp fiash is empty or corrupted (it means, any software inside IC running).
1. RS-232C Method Description (HyperTerminal).
The hardware tools requirement are:
1. A Modem-null (Cross type) DB9 female to DB9 female cable.
2. An adaptor DB9 male to mini-Din 9 pin male cable (Sharp Code: QCNWGA015WJPZ)
3. Make the connections as indicated in the figure:
Before using RS-232C updating method is necessary to configure a Terminal PC software. HyperTerminal has been selected as a Terminal soft-
ware because it's include in all Windows versions as an accessory, and you can find it inside "Accessories\Communications" folder. For this rea-
son, please follow carefully the next steps:
1) First time HyperTerminal is used, it's necessary to configure some settings. Follows next action to configure two connection: low speed
(9600bps) and high speed (115200bps).
2) Create a New Connection file with name "P55_9600bps".
3) Select a free COM port and select the Port Settings properties as follows: