SPECIFICATIONS
Performance
Sensitivity (volts RMS) for full rated power at 4
ohms: 1.25 V.
Frequency Response (at 1 watt) 22 Hz to
20 kHz: +0 dB, –1 dB.
Signal-to-Noise Ratio (20 Hz to 20 kHz, inputs
terminated)
A-weighted, below rated power: > 100 dB.
No weighting, below rated power: > 95 dB.
Total Harmonic Distortion (THD): < 0.5%.
Intermodulation Distortion (IMD):
(60 Hz and 7 kHz at 4:1) from full rated output to
–40 dB: < 0.3%.
Damping Factor (8 ohm) 10 Hz to 400 Hz: > 200.
Crosstalk (below rated power)
at 1 kHz: –75 dB.
at 20 kHz: –50 dB.
Input Impedance (nominal): 20 kilohms balanced,
10 kilohms unbalanced.
Load Impedance:
XLS 202, 402, 602, 802: 4 to 8 ohms per chan-
nel in Stereo, 8 ohms in Bridge Mono.
XLS 5000: 2 to 8 ohms per channel in Stereo, 4
to 8 ohms in Bridge Mono.
AC Line Voltage and Frequency Configurations
Available (±10%): 120V-60 Hz, 100V-50/60 Hz,
220V-50 Hz, and 230-240V.
Front Panel Controls and Indicators
Level: Two front-panel rotary level controls, one
for each channel.
Power: On when in the IN position.
T
he XLS Series of power amplifiers from Crown represents a new era in affordable, quality power
amplification. The line consists of five models in a uniform, rugged 2U chassis (3U for the XLS
5000), incorporating the best of tried-and-true design principles and innovative features.
Signal Presence Indicators: Two green LEDs, one
for each channel, illuminate when the channel's
input signal exceeds –40 dBu.
Clip Indicators: Two red LEDs, one for each chan-
nel, illuminate when the channel's output is being
overdriven.
Power Indicator: Blue LED indicates amplifier
has been turned on and AC power is available.
Fault Indicator: Two red LEDs, one for each chan-
nel, illuminate when amplifier is in protect mode.
Also illuminates briefly during normal power-up
when amplifier is first switched on.
Back Panel Connectors and Controls
Input Connectors: One per channel; three-pin
female XLR input connectors.
Output Connectors: Two 4-Pole Speakon
Connectors accept 2-pole or 4-pole Speakon con-
nectors. The top Speakon connector is wired for
both channels so it can be used for bridge-mono
wiring or for stereo wiring of two speakers to a
single Speakon connector.
One pair of binding posts per channel; accepts
banana plugs or bare wire. (European models do
not accept banana plugs.)
Circuit Breaker: Provides overload protection.
Mode Switch: Selects Dual or Bridge-Mono mode.
Protection
XLS Series amplifiers provide extensive protection
and diagnostic capabilities, including output current
limiting, DC protection, circuit breaker, and thermal
protection.
Cooling
Internal heat sinks with forced-air cooling for rapid,
uniform heat dissipation. Flow-through ventilation
from front to back.
Dimensions (XLS 202, 402, 602, 802)
EIA Standard 19-inch (48.3-cm) rack mount width
(EIA RS-310-B), 3.5-inch (8.9-cm) height and 15.2-
inch (38.6-cm) depth.
Dimensions (XLS 5000)
EIA Standard 19-inch (48.3-cm) rack mount width
(EIA RS-310-B), 5.25-inch (13.3-cm) height and
15.5-inch (39.5-cm) depth.
Weight
Net Weight:
XLS 202: 23.0 lb (10.4 kg).
XLS 402: 25.7 lb (11.7 kg).
XLS 602: 29.0 lb (13.2 kg).
XLS 802: 35.5 lb (16.1 kg).
XLS 5000: 62.0 lb* (27.7 kg)*.
®
Output
Shipping Weight:
XLS 202: 28.0 lb (12.7 kg).
XLS 402: 30.7 lb (13.9 kg).
XLS 602: 34.0 lb (15.4 kg).
XLS 802: 40.5 lb (18.4 kg).
XLS 5000: 62.0 lb (27.7 kg).
Regulatory Certifications
except
XLS 5000
XLS 5000
only
Other Applications
Note: Specifications apply to units in Stereo mode with
8-ohm loads and rated input sensitivity unless other-
wise specified.