SPECIFICATIONS
Performance
Frequency Response (at 1 watt from 4-ohm tap):
70 Hz to 19 kHz +/- 1 dB.
Frequency Response (at line out): 20 Hz to 20 kHz
+/- 1 dB.
Power Bandwidth (at 4-ohm tap, 2 dB below
maximum 1 kHz power): 50 Hz to 20 kHz with
< 0.5% THD
Signal to Noise Ratio (ref. to rated power, master
volume at minimum): 85 dB.
DC Output Offset: < ±5 mV.
THD: Less than 0.5% at rated power at 1 kHz.
Input Sensitivity (for full output at maximum
gain): 800 mV.
Input Impedance (nominal): 100 kilohms.
Minimum Load Impedance:
100V output: 160 ohms
70V output: 80 ohms
4-ohm output: 4/8 ohms
Crosstalk (all controls at "10"): –70 dB at 1kHz.
Line Output Level (nominal): 1V into 10 kilohms.
AC Line Voltage and Frequency Configurations
Available:
100V 50/60 Hz.
120V 60 Hz.
220V 50/60 Hz.
230V 50/60 Hz.
240V 50/60 Hz.
Operating Temperature/Humidity: 0° C to 40° C
at 95% relative humidity (non-condensing).
Storage Temperature: –20° C to 85° C.
Front Panel Controls and Indicators
Power Switch: Push-button on-off switch. The
power switch does not affect the 24V DC auxiliary
power input.
Power Indicator: Blue LED indicates power on.
®
T
he Crown
180A, 280A and 1160A are high-value amplifiers for commercial and industrial audio.
They provide 4-ohm and constant-voltage outputs (70V and 100V). The amps are part of Crown's
Commercial Audio Series, which also includes mixers and mixer-amps. These low-cost units provide
all necessary features in a simple building-block format.
Output Signal Presence Indicator: Green LED,
one for each output channel, illuminates when out-
put signal level exceeds 100 mV (45 dB below full
power) from the 4-ohm tap.
Clip Indicators: Red LED, one per output channel.
Illuminates at threshold of audible distortion.
Master Volume Controls: One per output channel.
Detented potentiometer with knob.
Tone Controls: Bass and Treble non-detented
potentiometers on each channel. Bass ±10 dB at
100 Hz, Treble ±10 dB at 10 kHz.
Back Panel Controls and Connectors
Reset Switch: Resets the circuit breaker that pro-
tects the power supply. 220/230/240V units have a
fuse instead.
AC Power Inlet: Detachable IEC.
Auxiliary Power Input: 2-position terminal strip
for 24 VDC (±10%) backup power. Accepts up
to 14 AWG terminal forks.
Amplifier Outputs Connectors: One per channel,
4-position terminal strip with COM (Common),
4 ohms, 70V and 100V terminals. Accepts up
to 10 AWG terminal forks. Non-touch cover
included.
Output VCA Connector: One for every two chan-
nels, 4-pin Phoenix-type connector for two
VCA control lines of +10 VDC and ground.
Compatible with Crown 1-VCAP and 4-VCAP
modules.
Line Out Connector: One 3-pin balanced
Phoenix-type connector per output channel.
Post master, pre-VCA. Level controlled by mas-
ter volume control.
Amp Input Connector: 3-pin Phoenix-type, high-
impedance balanced, one per amplifier channel.
Cooling
Convection cooled.
Protection
Current Limit Protection: Included.
Thermal Limit Protection: Over-temperature
thermal cutout.
DC-Fault Load Protection: Included.
Included Accessories
Power cord.
Detachable rack ears.
Screws for rack ears.
Non-touch cover for output connectors.
Phoenix-type connectors.
Spade lugs.
Optional Accessories
1-VCAP remote volume control for one channel.
4-VCAP remote volume control for four channels.
Dimensions
Width (without rack ears): 17.3 in. (43.8 cm).
Width (with rack ears): EIA Standard 19 in. (48.3-
cm) W (EIA RS-310-B).
Height (front panel): 3.5 in. (8.9 cm).
Height (including feet): 4.1 in. (10.5 cm).
Depth (front panel to back panel): 12.2 in. (31.0
cm).
Depth (front of knobs to back of non-touch cover):
13.9 in. (35.2 cm).
Weight
Net Weight:
180A: 21.0 lb (9.5 kg).
280A: 25.3 lb (11.5 kg).
1160A: 25.3 lb (11.5 kg).
Shipping Weight:
180A: 26.0 lb (11.8 kg).
280A: 30.3 lb (13.7 kg).
1160A: 30.3 lb (13.7 kg).
Regulatory Certifications
Note: All measurements are related to 120VAC units 60
Hz in stereo mode with 8-ohm loads at 1 kHz at rated
power unless other otherwise specified. Specifications
for units supplied outside the U.S.A. may vary slightly
at different AC voltages and frequencies.