Haier AS25THMHRA-C Service Manual page 306

Hide thumbs Also See for AS25THMHRA-C:
Table of Contents

Advertisement

10.3 Error Codes and Description indoor display
Indoor displaying panel code indication
Other display
Indoor and
Outdoor
E7
Directly display
E1
Directly display
Indoor
E2
Directly display
Malfunction E4
Directly display
E14
Directly display
E5
Trouble record
E9
Trouble record
F12
Directly display
F1
Directly display
F22
Directly display
F3
Directly display
F20
Trouble record
F19
Trouble record
F27
Directly display
F4
Directly display
F8
Trouble record
F21
Directly display
F7
Directly display
Outdoor
Malfunction
F6
Directly display
F25
Directly display
F13
Trouble record
F14
Trouble record
F11
Directly display
F28
Directly display
F15
Trouble record
F2
Trouble record
F23
Trouble record
F9
Trouble record
F24
Trouble record
F34
Trouble record
F35
Trouble record
F43
Code indication
Only For 498 and
498A display
(Red/Green Time
Run □On★Flash■
Off)
□ ★
■ ★
■ ★
★ ■
★ ■
★ ■
★ □
★ □
★ ■
★ ■
★ □
□ ★
★ ■
★ ■
□ ■
★ □
★ □
★ ■
★ ■
★ □
★ □
★ □
/
■ ★
/
★ □
/
★ ■
Outdoor
fault description
(LED1 flash
times)
Communication fault between
15
indoor and outdoor units
/
Indoor temperature sensor failure
/
Indoor coil sensor failure
/
Indoor eeprom failure
/
Indoor fan failure
22
Internal unit antifreeze protection
21
Internal unit overload
1
Eeprom failure
2
IPM failure
3
AC current overcurrent protection
Communication error between
4
module board and main PCB
board.
5
High pressure protection
Power over/under voltage
6
protection
Compressor stall / press
7
instantaneous stop
Compressor discarging
8
temperature protection
9
Abnormal of DC motor
10
Abnormal of piping sensor
11
Suction temperature sensor failure
Abnormal of outdoor ambient
12
sensor
Abnormal of compressor
13
discharge sensor
16
Lack of refrigerant
17
4-way valve reverse failure
18
Compressor jam (only for spdu)
19
Module PWM select circuit error
Outdoor terminal block
20
temperature protection
Instantaneous over-current
24
protection of the compressor
Compressor U-phase overcurrent
25
Compressor V-phase overcurrent
Compressor W-phase overcurrent
26
Module reset
27
CT disconnection
37
Outdoor coil protection
38
Compressor driver board failure
46
Model matching abnormality
28
Service diagnosis
Reference
Page
Page.39
Page.29
Page.29
Page.30
Page.31
Page.42
Page.30
Page.34
Page.35
Page.36
Page.37
Page.38
Page.32
Page.29
Page.29
Page.29
Page.29
Page.41
Page.41
Page.35
Page.35
Domestic air conditioner
/
/
/
/
/
/
/
/
/
/
/

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

Table of Contents