11.2 Cooling power consumption value- temperature curves
indoor temp.
DB/WB
21/15℃
24/16℃
27/19℃
30/22℃
32/23℃
35/24℃
1500
1300
1100
900
700
500
300
100
performance curves
power consumption value-temp.table
10℃
15℃
20℃
639
633
622
657
635
621
698
696
666
719
704
688
733
724
707
744
726
707
power consumption and temp.curves
indoor temp.(DB/WB)
outdoor temp.
25℃
30℃
35℃
375
524
675
384
537
692
419
597
748
428
604
771
460
649
807
467
665
848
49
Performance and curves diagrams
38℃
40℃
824
952
840
964
897
1032
920
1087
997
1150
1048
1188
Domestic air conditioner
43℃
1021
1045
1145
1161
1229
1271
10℃
15℃
20℃
25℃
30℃
35℃
38℃
40℃