Download Print this page

Advertisement

Quick Links

OA-AXIS I / II
Manufacturer's statement
Read this operation manual carefully before use to ensure proper operation of this product.
Failure to read this operation manual may cause improper operation and may result in serious injury or death of a person.
The meanings of the symbols are as follows.
Failure to follow the instructions that accompany this indication and improper handling
WARNING
may result in serious injury or death.
Failure to follow the instructions that accompany this indication and improper handling
CAUTION
may result in injury and/or damage to property.
NOTE
Pay special attention to sections with this symbol.
NOTE
1. This sensor is a non-contact switch intended for header mount/wall mount of an automatic door.
Do not use for any other applications. This sensor cannot be used for industrial doors or shutters,
when used, proper operation and safety cannot be guaranteed.
2. When setting the sensor's detection area, make sure there is no traffic around the installation site.
3. Before turning the power ON, check the wiring to prevent damage or malfunction of equipments that
are connected to the sensor.
4. Only use the sensor as specified in the operation manual provided.
5. Be sure to install the sensor in accordance with the local laws and standards of the country in which
the sensor is installed.
6. Before leaving the job site make sure that the sensor is operating properly and instruct the building
owner/operator on proper operation of the door and the sensor.
7. The sensor setting can only be changed by an installer or service engineer. When changed, register
the changed setting and dates in the maintenance logbook accompanying the door.
The following conditions are not suitable for sensor installation.
Fog,
Exhaust
Wet
Vibration
Objects
Specifications
Model
: OA-AXIS I/OA-AXIS II
Cover color
: Silver/Black
Mounting height
: 2.0 (6'7") to 3.5 m (11'5")
Detection area
: See Detection area
Detection method
: Active Infrared Reflection
Depth angle
: 1st to 3rd rows : -6° to +6°
adjustment
4th and 5th rows : +26° to +44°
Power supply
: 12 to 24 VAC (±10%)
12 to 30 VDC (±10%)
Power consumption
: OA-AXIS I < 3 VA
OA-AXIS II < 4 VA
: See Operation indicator table
Operation indicator
Output hold time
: Approx. 500 ms
Response time
: < 300 ms
Operating temperature
: -20 to +55°C (-4 to 131°F)
Operation indicator table
Status
Operation indicator color
Stand-by (Installation mode)
Stand-by (Operation mode)
1st row detection
2nd row detection
3rd, to 5th row detection
Signal saturation
Slow Green blinking
NOTE
The specifications herein are subject to change without prior notice due to improvements.
Outer dimensions and part names
267(10 1/2")
125(4 15/16")
36
(1 7/16")
(1 11/16")
(1)
(3)
(4)
(1) Connector
(2) Mounting holes
(3) Operation indicator
(4) Depth angle adjustment screw
(5) Width adjustment screws
(6) Dipswitches
(7) Detection window
(8) Area adjustment tool
5915033 DEC 2021
WARNING
Danger of electric shock
Do not wash, disassemble,
rebuild or repair the sensor,
otherwise it may cause electric
shock or breakdown of the
equipment.
Reflection
Output
: OA-AXIS I
Form C relay
50 V 0.3 A Max.(Resistance load)
OA-AXIS II
1st to 3rd rows : Form C relay
50 V 0.3 A Max. (Resistance load)
3rd to 5th rows : Form C relay
50 V 0.3 A Max.(Resistance load)
IP rate
: IP44
Weight
: 320 g (11.2 oz)
Accessories
: 1 Cable 3 m (9'10")
1 Operation manual
2 Mounting screws
1 Mounting template
1 Area adjustment tool
Yellow
Green
Red blinking
Red
Orange
43
45(1 3/4")
(2)
(5)
(6)
(7)
(8)
Detection area
ENGLISH
Mounting
surface
Motion/presence
detection
Motion detection
Sensor setting
1st to 3rd rows
4th and 5th rows : +44°
A
B
C
D
E
F
G
H
I
NOTE
The actual detection area may become smaller depending on the ambient light, the color/material of the
object or the floor as well as the entry speed of the object.
*The values of the chart above is of the emitting spots, but not of the detection area.
Installation
1. Mounting
a. Place the mounting template at the desired mounting position.
b. Drill two mounting holes of ø3.4 mm (ø1/8").
c. To pass the cable through to the header, drill a wiring hole of ø8 mm (ø5/16").
d. Remove the mounting template.
e. Remove the housing cover. Attach the sensor to the mounting surface with two mounting screws.
Header
Sensor
Y
X
Door
Floor
Maximum mounting distance (Y)
X
0.05 (2")
0.10 (4")
0.15 (6")
0.20 (8")
0.25 (10")
0.30 (12")
Make sure to affix the mounting template as described in the above chart, otherwise it can be dangerous since there
may be no detection area around the threshold. Install the sensor as low as possible on the header.
NOTE
The sensor mounting position may be limited depending on the header thickness and the mounting
height.
2. Wiring
Wire the cable to the door controller properly as shown in the drawing below.
OA-AXIS I
OA-AXIS II
[mm (inch)]
Before starting the procedure, make sure that the power is turned OFF. When passing the cable through the hole, do
not tear the shield otherwise it may cause electric shock or breakdown of the sensor.
3. Turn ON the power
a. Plug the connector.
b. Supply power to the sensor. Adjust the detection area and set the dipswitches. (See Adjustments)
NOTE
Make sure to connect the cable correctly to the door controller before turning the power ON.
When turning the power ON or after adjusting the settings, do not enter the detection area for more than
10 s in order to enable the presence detection.
4. Mounting the housing cover
Place the housing cover.
If wiring is to be exposed, break
the knockout.
A
1st row
2nd row
3rd row
4th row
5th row
G
G
H
: +6°
I
2.20 (7'3")
2.50 (8'2")
2.70 (8'10")
0.14 (6")
0.16 (6")
0.18 (7")
0.42 (1'5")
0.48 (1'7")
0.52 (1'8")
0.82 (2'8")
0.93 (3'1")
1.00 (3'3")
1.35 (4'5")
1.54 (5'1")
1.66 (5'5")
1.90 (6'3")
2.17 (7'1")
2.34 (7'8")
1.33 (4'4")
1.51 (4'11")
1.63 (5'4")
2.05 (6'9")
2.32 (7'7")
2.51 (8'3")
2.78 (9'1")
3.15 (10'4")
3.40 (11'2")
MOUNTING TEMPLATE
H
H : Height from the floor to the bottom of the header.
Y : Distance between the bottom of header and the sensor.
X : Distance between the door and the mounting surface.
H
2.00 (6'7")
2.20 (7'2")
2.50 (8'2")
0
No limit
0.20 (8")
0.20 (8")
0.20 (8")
0.20 (8")
0.20 (8")
0.20 (8")
0.13 (5")
0.15 (6")
0.17 (7")
-
0.11 (4")
0.13 (5")
-
-
-
-
CAUTION
Risk of getting caught
Grey
Grey
White
Yellow
Green
Grey
Grey
White
Yellow
Green
White Str.
Yellow Str.
Green Str.
*The outputs from the 3rd row overlaps.
WARNING
Danger of electric shock
WARNING
Do not use the sensor without the cover. When using the cable knockout,
install the sensor indoors or use the rain cover (Separately available)
otherwise electric shock or breakdown of the sensor may occur.
: Emitting spots
: Emitting spots
(Can be elminated)
: Detection area
B
C
D
E
F
[m(feet,inch)]
3.00 (9'10")
3.50 (11'6")
0.20 (8")
0.23 (9")
0.58 (1'11")
0.67 (2'2")
1.10 (3'7")
1.30 (4'3")
1.85 (6'1")
2.16 (7'1")
2.60 (8'6")
3.03 (9'11")
1.81 (5'11")
2.11 (6'11")
2.79 (9'2")
3.26 (10'8")
3.79 (12'5")
4.42 (14'6")
[m (feet,inch)]
3.00 (9'10")
0.20 (8")
0.20 (8")
0.20 (8")
0.15 (6")
-
0.12 (5")
-
-
Power supply
}
12 to 24 VAC ±10 %
12 to 30 VDC ±10 %
COM.
N.O.
N.C.
Power supply
}
12 to 24 VAC ±10 %
12 to 30 VDC ±10 %
COM.
3rd to 5th rows output *
N.O.
N.C.
COM.
1st to 3rd rows output *
N.O.
N.C.
Danger of electric shock