Pioneer PL-L70 Service Manual page 55

Hide thumbs Also See for PL-L70:
Table of Contents

Advertisement

The band detector doesn't
work during tracing
Is it a special type of record listed below?
YES
Recheck it with a regular record
Perform error checks on S16, R12, R22
and
R41
to 43 and check the patterns
around those areas
When
the sensor sensitivity is changed
| NO
does the voltage of Q6 pins 8 and 10
(pin
10 as reference)
change as shown
below?
(+5V as reference)
H
N
L
approximate-
—0.9
—1.3V
ly —0.6
Perform
error checks on R23 and Q11,
and
check
the
patterns
around
those
areas
Readjust
the
band
sensor
offset
VR3
Readjust the band sensor gain VR1, 2
The band detector doesn't
work
in the UP mode
Is it a special type of record listed below?
NO
Is it the same when the sensor sentivity
is changed?
YES
Recheck it with a regular record
Change the sensitivity and recheck
When
the sensor
sensitivity
is changed
does
the voitage
of O6
pins 8 and 10
(pin 10 as reference)
change as shown
below? (+5V as reference)
Perform
error checks on S16, R12 and
H
N
L
R41
to R43, then check the patterns in
i
those areas
approximate-
—0.6V
—0.8V
ly —0.4V
YES
NO}
Check
the stylus
height.
It should
be
6mm
above the surface of the record +
imm
Readjust the stylus
heigh
Special types of records
eight
e@
Color records
Picture records
e
@
Records with extremely narrow bistds
e
Records with extremely jagged sosnd
Readjust
the
band
sensor
offset
VR3
grooves
e@
€xtremely dirty or scratched recy rds
Readjust the band sonsor gain VR1, 2
71