Download Print this page

Current Tetra GECLPSPH-2 Installation Manual page 4

Control module

Advertisement

Tetra
LED Control Module GECLPSPH-2
®
Specifications
Performance Data
Input Voltage (VDC)
Input Current (A)
Output Voltage (VDC)
Output Current (ADC)
Output Power (W)
Environmental Operating Temperature Range
Environmental Humidity (non-condensing)
Environmental Storage Temperature Range
Dimensions
*Maximum case temperature is 85°C
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference,
and (2) this device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be
required to correct the interference at his own expense.
This Class [A] RFLD complies with the Canadian standard ICES-005. Ce DEFR de la classe [A] est conforme à la NMB-005 du Canada. 
Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment.
Current Lighting Solutions, LLC
Beachwood, OH 44122
Min
23
-
2.1
-
-
-40°C
0%
-40°C
www.LED.com
© 2023 Current Lighting Solutions, LLC. All rights reserved. GE and the GE monogram are trademarks of the
General Electric Company and are used under license. Information provided is subject to change without
notice. All values are design or typical values when measured under laboratory conditions.
Nominal
24
-
-
-
-
+25°C
-
-
9.5 in. x 1.7 in. x 1.2 in. (241 mm x 43.2 mm x 30.5 mm)
Installation Guide
Max
25
3
4.1
4.0
32.8
+55°C*
95%
+85°C