Download Print this page

Current Tetra GECLPSPH-2 Installation Manual page 3

Control module

Advertisement

Tetra
LED Control Module GECLPSPH-2
®
White to white or blue
Green to
green
AC line
Wire AC line to LED driver(s) in
5
accordance with the applicable
local, state, and country electrical
codes. Connect black to black or
brown, white to white or blue,
and green to green using 18 AWG
(0.82mm2) wire connectors.
Dip Switch Settings
8
Turn power off. Only the first position dip switch is enabled - the other five position
switches are disabled
NOTE: For proper operation, verify that only one switch is set to the "ON" position.
9
Replace the dip switch cover and perform a quick test by turning the system on to
ensure the channel letter LEDs are lit.
CAUTION: Only dip switch 1 should be in the 'on' position.
All other dip switches are inactive and should be in the 'off'
position. If these requirements are not followed the warranty
for the LED driver will be voided.
Notes
• Do not connect outputs in series or parallel.
• Power off the LED control module when setting the dip switches.
• When installing power supply, connect to the appropriate sized building breaker or disconnect device for line and neutral
connections, in accordance with local, state or country regulations.
• The grounding and bonding of the power supply and overall sign shall be done in accordance with National Electric Code (NEC)
Article 600.
Black to black
or brown
LED driver
Black or blue (-)
Connect the red stripe wire (+)
6
of the LED control module to the
red wire (+) of the power supply.
Connect the white wire (-) of the
LED control module to the black
or blue wire (-) of the power
supply.
Red (+)
Red stripe (+)
LED control module
White (-)
7
Loading Information
Maximum Loading
GECLPSPH
17 modules per output
68 modules total
3
Installation Guide
To LED modules
Inline connector
Cap unused leads
Connect each LED control module
output lead pair to each Tetra LED
module supply lead pair using
UL certified wire connectors. Cap
each unused output lead with a UL
certified wire connector.
WARNING: Do not connect
outputs in series or parallel.
GECLPSPHA
17 modules per output
17 modules total

Advertisement

loading