EN 28
5.
QFU2.1E LA
Quality items
Signal quality. Bad / average /good (not for DVB-S).
Ethernet MAC address. Displays the MAC address
present in the SSB.
Wireless MAC address. Displays the wireless MAC
address to support the Wi-Fi functionality.
BDS key. Indicates if the set is in the BDS status.
CI module. Displays status if the common interface
module is detected.
CI + protected service. Yes/No.
Event counter :
S : 000X 0000(number of software recoveries : SW
EVENT-LOG #(reboots)
S : 0000 000X (number of software events : SW EVENT-
LOG #(events)
H : 000X 0000(number of hardware errors)
H : 0000 000X (number of hardware events : SW EVENT-
LOG #(events).
Coldboot counter. Neglect "BDS mode settings"
Fastcoldboot counter. Neglect "BDS mode settings"
Hotboot counter. Neglect "BDS mode settings"
Application hotboot counter. Neglect "BDS mode
settings"
On
2013-Apr-05
Service Modes, Error Codes, and Fault Finding
Mains
off
- WakeUp requested
- Acquisition needed
St by
- stby requested and
no data Acquisition
required
Figure 5-4 Transition diagram
How to Exit CSM
Press "MENU" (or "HOME") / "Back" key on the RC-transmitter.
5.3
Start-up
As described, the start-up diagrams below, documents which
supplies are present at any certain moment.
Off
Mains
on
Semi
St by
GoToProtection
(triggered during startup
by standby µP)
GoToProtection
back to
div. table
WakeUp
requested
Active
St by
requested
WakeUp
requested
(SDM)
GoToProtection
Protection
19210_076_120504.eps