Electrical Rough-in

2
Locate the multi-conductor cable (supplied with steam generator). Carefully route this interface cable from the
steam generator to the 5CN-550L, 5CH-550L or 5CB-550L digital interface located inside the steam room (see
Figure 1). Route this interface cable through a ¾" conduit to protect the cable from damage and to facilitate
replacement if necessary.
3
Interface and Cable Installation
1. Locate the previously installed cable and black plastic strain relief clamp. Locate the knockout on the
steam generator for the interface cable (see Figure 2).
2. Place strain relief around cable about seven inches from the end and insert into the hole.
3. Remove the protective cap from the multi-conductor cable plug. Connect the cable to the modular jack.
4. Close and secure the steam generator cover.
5. Locate the modular jack at the female coupler on back of the 5CN-550L, 5CH-550L or 5CB-550L digital
interface. Check that the orientation of the plug properly aligns with the jack. A snap will indicate the plug
is installed correctly (see Figure 3).
6. Peel adhesive liner from back of the interface. Apply silicone (supplied) into around the back edge of the
interface to form a watertight seal (see Figure 3).
7. Apply the interface to the wall. Press firmly and hold for a few seconds. Wipe the excess silicone from
around the interface.
IMPORTANT: The 5CN-550L, 5CH-550L & 5CB-550L digital interfaces have built in temperature sensors and
therefore MUST be installed inside the steam room.
IMPORTANT: The adhesive on the back of the 5CN-550L, 5CH-550L & 5CB-550L digital interfaces will NOT
seal this interface. It is the responsibility of the installer to seal this interface to the wall with the supplied sili-
cone. Water damage to the interface is not covered by the warranty.
IMPORTANT: 5CN-550L, 5CH-550L & 5CB-550L digital interfaces cable MUST plug directly into the steam
generator. Do NOT plug this interface into the optional 5SP-MU audio speaker system.
Temperature settings: 60ºF min to 125ºF max
Maximum Time setting: 60 Minutes
Figure 2 - Cable Installation on Generator
114570 Rev. A
WARNING
!
Test the interface for operation before
continuing on to the next step.
3/4" Conduit
To interface
Modular Jacks:
All modular jacks are
identical and work in
any combination.
Connect to any jack.