Buffer Tank Connection; Base Pan Heater; Alternative Outdoor Sensor; Bivalent Connection - Panasonic WH-ADC0309J3E5ANC Operating Instructions Manual

Air-to-water hydromodule+tank
Table of Contents

Advertisement

Available languages

Available languages

Menu

Buffer tank connection

5.6
To connect tank to the system
and if selected YES, to set
T temperature.
• The optional PCB connectivity
must be selected YES to
enable the function.
• If the optional PCB
connectivity is not selected,
the function will not appear on
the display.

Base pan heater

5.7
To select whether or not
optional base pan heater is
connected.
* Type A - The base pan heater
activates only during
deice operation.
* Type B - The base pan heater
activates when outdoor
ambient temperature is
5 °C or lower.

Alternative outdoor sensor

5.8
To select an alternative outdoor
sensor.

Bivalent connection

5.9
To select to enable or disable
bivalent connection.
Yes
To select either auto control
pattern or SG ready input
control pattern.
* This selection only display
to select when optional pcb
connection set to Yes.
Default Setting
Setting Options / Display
No
Yes
Set T for Buffer
5 °C
Tank
No
Yes
Set base pan heater
A
type*.
No
No
Auto
EN
25

Advertisement

Table of Contents
loading

Table of Contents