CHECK
RESULT
CAUSE
REMEDY
2. 240V AC is applied to primary side of high voltage transformer.
No continuity
Defective magnetron
Replace
Disconnect one lead wire con-
nected to filament terminal of
magnetron and check the con-
tinuity of magnetron's filament
Check the 0.5A fuse
between H.V.Capacitor
0.5A fuse open
and magnetron
als of magnetron and check
the continuity between filament
and magnetron case
b e
a s
Replace diode assy with 0.5A
Check the 0.5A fuse with diode
0.5A fuse open
fuse
NOTE:
Check the continuity of the
eke
.
'
a
nae
Open winding of the high vol-
high vottage transformer prim
No continuity
tage transformer
Replace
ary winding (0—240
Check the insulation of filament
Detective high voltage trans-
winding of high voltage trans-
Poor insulation
Replace
former
former
Check the continuity of fila-
ment winding of H.V.Trans-
No continuity
Defective H.V.Transformer
Replace
former
Normal
Aging change of magnetron
Replace magnetron
NOTE: 0.5A fuse will be open when diode is shorted in order to prevent from overheating of H.V. Transformer. Therefore, in this case, diode may be
possibly shortcircuited.
{TROUBLE 4] Microwave output power is low. First of all, check if output is really low by following "Measurement of
microwave output" on page 25.
CHECK
RESULT
CAUSE
REMEDY
Lower than 220 volts (in the 240
volts area)
Decrease in power source vol-
tage
inform customer of required
tage with magnetron oscil-
lating.
Defective digital programmer
circuit
Check the timing periods of
the 18V DC being applied to
the power relay 5 coil (Refer to
page 10 for the timing periods
of the power relay 5)
Abnormal
Replace
Replace depending on the re-
Aging change of magnetron