Download Print this page

Control Board; Cb Board - Ferroli OMNIA M 3.2 Installation Manual

Hydraulic electronic board box
Hide thumbs Also See for OMNIA M 3.2:

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 9
HYDRAULIC ELECTRONIC BOARD BOX

5. CONTROL BOARD

5.1 CB board

1
CN21
Order
Port
Code
1
CN21
POWER
Port for power supply
2
CN5
GND
Port for ground
3
CN25
DEBUG
Port for IC programming
T2
Reserved
T2B
Reserved
TW_in
Reserved
4
CN6
TW_out
Reserved
Port for temperature sensor of final outlet water tempe-
T1
rature
5
CN24
Tbt
Port for temperature sensor of balance tank
6
CN23
RH
Port for humidity sensor (Reserved)
7
CN13
T5
Port for domestic hot water tank temp. sensor
8
CN15
Tw2
Port for outlet water for zone 2 temp. sensor
Port for temperature sensor (Reserved)
9
CN38
T52
10
CN18
Tsolar
Port for solar panel temp sensor
K1 K2
Input port (Reserved)
11
CN66
S1 S2
Input port for solar energy
10V GND Reserved
HT
Control port for room thermostat
12
CN31
COM
Power port for room thermostat
CL
Control port for room thermostat
SG
Port for smart grid (grid signal)
13
CN35
EVU
Port for smart grid (photovoltaic signal)
M1 M2
Port for remote switch
14
CN36
T1 T2
Reserved
NOTE
If the Tbt and T5 terminals need to be connected, you can unplug the connecting wire from the corresponding position on the Hydraulic module board and
plug it into the kit PCB board port.
2
3
CN5
CN25
1
2
3
4
5
6
7
8
13
14 15
16
17
18
19
CN11
16
Description
Cod. 3540001190 - Rev. 00 - 11/2023
4
CN24
CN6
CN13
CN15
CN18
9
10
11
12
1
2
3
20
21
22 23 24
7
6
CN30
fig. 4 -
Order
Port
Code
3 (X/HA)
4 (Y/HB)
15
CN30
6 (P) 7(Q) Reserved
9 (H1)
10 (H2)
1 (AHS1)
2 (AHS2)
3 (1ON)
4 (2OFF)
17 (C1)
5 (2ON)
6 (2OFF)
18 (C1)
7 (3ON)
8 (3OFF)
19 (C1)
9 (P_c)
20 (C1)
16
CN11
10 (P_o)
21 (C1)
11 (P_s)
22 (C1)
12 (P_d)
23 (C1)
13 (TBH)
16 (C1)
14 (IBH2)
16 (C1)
15 (IBH1)
17 (C1)
24 (P_X)
23 (C1)
5
6
CN23
7
8
9
CN38
10
11
CN66
12
CN31
13
CN35
CN36
14
4
5
E
X/HA
Y/HB
10
8
9
15
Description
Port for communication with hydraulic module board
Reserved
Port for additional heat source
Port for SV1(3-way valve)
Port for SV2(3-way valve)
Port for SV3(3-way valve)
Port for zone 2 pump
Port for outside circulation pump
Port for solar energy pump
Port for DHW pipe pump
Control port for tank booster heater
Control port for internal backup heater 1
Control port for internal backup heater 2
Output port for alarm/Defrost run
EN
13

Advertisement