Wiring Diagram 120V - Grizzly G0964 Owner's Manual

1-1/2 hp portable fume extractor w/precision arm
Table of Contents

Advertisement

Neutral
Hot
120 VAC
Ground
5-20 Plug
Figure 45. Magnetic switch wiring (120V).
Figure 46. Motor junction box wiring (120V).
Model G0964 (Mfd. Since 04/23)

Wiring Diagram 120V

98
2T1
97
4T2
96
6T3
95
MAG SWITCH 120V
NHD MS1-18D2E7N212PBVO
17
2T1
18
21
20
OL Relay
4T2
NHD
NTH-21
2PE
6T3
A2
14NO
1
3
Start
Capacitor
400MFD
125VAC
Prewired 120V
MOTOR 120V/240V
READ ELECTRICAL SAFETY
ON PAGE 32!
A1
Contactor
1L1
120V
3L2
NHD
C18D10E7
5L3
A2
NHD
13NO
18
17
1PS
GND
Ground
4
2
1
3
Run
Capacitor
50uF
250VAC
-33-