Table of Contents

Advertisement

fRont CoveR (1)

to Remove:
1. remove the face cover and free-arm cover (See page 8 and 9).
2. remove the SetScrewS (a) q (2 pcS.).
3. remove the SetScrewS (b) w (5 pcS.), back cover e.
4. remove the SetScrewS (c) r (2 pcS.).
5. looSen the SetScrew t.
6. diSconnect all the connectorS from the circUit board a.
note:
do not diSconnect the connectorS by pUlling on cord.
to diSconnect, graSp the connector, not the cord.
to attaCH:
7. follow the above procedUreS in reverSe.