Input Shunt Capacitance - Marconi Instruments TF 2337A Instruction Manual

Automatic distortion meter
Table of Contents

Advertisement

4.3.8
e)
Vary
the output voltage of
the
oscillator
so
that the
level
meter
of the
TF
2337A
reads
fiill
scale.
Note
this
reading
(E
in
the equation).
0
Connect
a 100
kn ±1%
resistor
in
a
series
with the input
to
the
TF
2337A.
Note
the
LEVEL METER
reading (V
in
the
equation).
g)
Input resistance {R
input)
of
the
TF
2337A
is
given as
follows
:
Vo
R
input =
E
-
V
^
^
h)
The
input
resistance
of the
TF
2337A
should be 100
kS2
±5%.
Input
Shunt
Capacitance
a)
Test equipment required
L
-
C meter
b)
Set the
controls of the
TF
2337A
as follows
;
-
Level range switch
-
0.3
V
c)
Connect
the
L
-
C
meter
to
the input
terminals
of the
TF
2337A.
Measure
the input
capacitance which should
be
less than 70
pF.
22
TF
2337A

Advertisement

Table of Contents
loading