Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
Marconi Instruments Manuals
Measuring Instruments
TF 2337A
Instruction manual
Band Rejection Filter - Marconi Instruments TF 2337A Instruction Manual
Automatic distortion meter
Hide thumbs
1
2
3
Table Of Contents
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
page
of
40
Go
/
40
Contents
Table of Contents
Bookmarks
Table of Contents
Advertisement
4.3.3
Band
Rejection
Filter
Pig.
4.
2
Fundamental
Rejection
Filter
check
(a)
Test equipment required
:
Low
distortion oscillator
,
Counter
(b)
Connect
the
TF
2337A
as
shown
in Fig.
4.2,
(c)
Set
TF
2337A
controls
as
follows
j-
Function switch
-
LEVEL
Level range
switch
-
IV
(d)
Connect
the output of
thelow
distortion oscillator
to the input of
the
TF
2337A.
<e)
Set the
frequency
of the
low
distortion oscillator
to
400
Hz
the level
meter
of the
TF
2337A
to
full
scale.
and,
varying
the output, set
-
(f)
Setthe switches
of the
TF
2337A
as follows
:
Function switch
-
400
Hz
'
'
Distortion
range switch-
0.1%
(g)
Vary
the
frequency
of
the
low
distortion
meter
so
that
the distortion
meter
of the
TF
2337A
indicates
0.
007%.
Check
the
frequency
at
two
points
(+
and
-)
of the
fundamental
frequency
to
confirm
that
the,
frequency
width
is
more
than ±3%:
(h)
Check
that
the
centre frequency
of the
two
points
noted
above
is
within
±1%
of
400 Hz.
i)
Select the
TF
2337A
controls as follows
:
-
Function switch
-
1,000 Hz.
i)
Sat the output
frequency
of the
low
distortion oscillator
to
1000
Hz
and, varying
the
frequency
set the
level
meter
of the
TF
2337A
to
full
scale.
k)
Select the
TF
2337A
controls
as
follows
-
Function switch
-
1000
Hz
Distortion
rar^e
switch
-
0.1%
l)
Cany
out
the
operation
described
in
para.
4. 3. 3(g).
Check
that the
centre frequency
of the
two
points
corresponding
to
0.007%
distortion
is
within
'
±1%
of
1000 Hz.
18
TF
2337A
Table of
Contents
Previous
Page
Next
Page
1
...
16
17
18
19
20
21
22
23
Advertisement
Table of Contents
Related Manuals for Marconi Instruments TF 2337A
Measuring Instruments Marconi Instruments tf2603 Instruction Manual
Electronic millivoltmeter (22 pages)
Measuring Instruments Marconi Instruments TF 2502 Instruction Manual
R.f. power meter (26 pages)
Measuring Instruments Marconi Instruments TF 2005R Instruction Manual
Af two-tone signal source (61 pages)
Measuring Instruments Marconi Instruments 933D Instruction Manual
Moisture meter (24 pages)
Measuring Instruments Marconi Instruments 2382 Operating Manual
100hz-400mhz spectrum analyzer and display (35 pages)
Related Products for Marconi Instruments TF 2337A
Marconi Instruments tf2603
Marconi Instruments TF 2502
Marconi Instruments TF 2005R
Marconi Instruments TF 2700
Marconi Instruments TF 2170B
Marconi Instruments TF 1066B/6
Marconi Instruments TF 1066B/6R
Marconi Instruments TF 995A/5
Marconi Instruments TF 1247
Marconi Instruments 2380
Marconi Instruments 2382
Marconi Instruments 52380-900E
Marconi Instruments 52382-900A
Marconi Instruments 933D
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL