LG THERMA V Installation Manual page 155

Air-to-water heat pump
Hide thumbs Also See for THERMA V:
Table of Contents

Advertisement

Function
Outdoor1,Heat
Heating lower ambient
(Out1)
temp
Outdoor2,Heat
Heating higher ambient
(Out2)
temp
Outdoor3,Cool
Cooling lower ambient
(Out3)
temp
Outdoor4,Cool
Cooling higher ambient
(Out4)
temp
Water1,Heat
Heating higher water
(LW1)
temp
Water 2,Heat
Heating lower water
(LW2)
temp
Water3,Cool
Cooling higher water
(LW3)
temp
Water4,Cool
Cooling lower water
(LW4)
temp
Air 1, Heat (RA1) Heating higher air temp
Air 2, Heat (RA2) Heating lower air temp
Air 3, Cool (RA3) Cooling higher air temp
Air 4, Cool (RA4) Cooling lower air temp
- Setting range: Celsius
- Seasonal Auto Driving mode: Heating, Heating & Cooling
* If heating mode is selected, heating & cooling or cooling can not be selected.
- Depending on the air / outflow control selection value, the water / air related setting value is
displayed on the screen.
Description
Use heater :
LW STD : 15~55 °C
EW STD : 15~50 °C
Not use heater :
LW STD : 20~55 °C
EW STD : 20~50 °C
Use FCU & 5 °C
IDU :
LW STD : 5~27 °C
EW STD : 10~27 °C
Use FCU & 6 °C
IDU :
LW STD : 6~27 °C
EW STD : 11~27 °C
Not use FCU :
LW STD : 16~27 °C
EW STD : 20~27 °C
Default
Range
(Circuit1)
-10 °C
-25 ~ 35 °C
10 ~ 46 °C
50 °C
40 °C
12 °C
10 °C
16 ~ 30 °C
18 ~ 30 °C
INSTALLER SETTING
Default
Boundary
(Circuit2)
Out1 ≤ Out2-1
Out2 ≥ Out1 +1
18 °C
Out2 ≤ Out3 -5
Out3 ≥ Out2 +5
30 °C
Out3 ≤ Out4 -1
Out4 ≥ Out3 +1
40 °C
LW1 ≥ LW2
35 °C
LW1 ≥ LW2
28 °C
LW3 ≥ LW4
18 °C
LW3 ≥ LW4
16 °C
RA1 ≥ RA2
21 °C
RA1 ≥ RA2
19 °C
RA3 ≥ RA4
21 °C
RA3 ≥ RA4
19 °C